YASKAWA CIPR-GA50C series Technical Manual page 467

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

The drive saves the parameters in
Table 12.17 Parameters Saved as User Parameters with the Traveling Preset
User Parameter No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
A2-10
A2-11
A2-12
8 : Conveyor 2
The drive automatically sets the parameters in
No.
A1-02
C1-01
C1-02
C6-01
L3-04
n3-13
n3-21
The drive saves the parameters in
Table 12.19 Parameters Saved as User Parameters with the Conveyor 2 Preset
User Parameter No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
Notes for Elevator Applications
When using the drive for elevator applications, read the safety descriptions and precautions, and safely and
correctly use the device.
Conditions to Open and Close the Brake
Set L4-07 = 0 [Speed Agree Detection Selection = No Detection during Baseblock] to open and close the holding
brake.
When L4-07 = 1 [Detection Always Enabled], the output frequency increases when you input the Run command
although the external baseblock command is input. Because of this, speed detection operates and will open the
brake signal.
YASKAWA SIEPC71061753A GA500 Technical Manual
Table 12.17
as User Parameters.
Parameter No. Saved
Table 12.18
Table 12.18 Best Parameter Settings for Conveyor 2 Application
Control Method Selection
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
Stall Prevention during Decel
OverexcitationBraking (OEB) Gain
HSB Current Suppression Level
Table 12.19
as User Parameters.
Parameter No. Saved
12.2 A: Initialization Parameters
b1-01
C1-01
C1-02
C6-02
d1-01
d1-02
d1-03
E2-01
H1-05
H1-06
H2-01
L1-01
for a conveyor 2 application.
Name
A1-02
b1-01
b1-02
C1-01
C1-02
E2-01
L3-04
n3-13
n3-21
Name
Frequency Reference Selection 1
Acceleration Time 1
Deceleration Time 1
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
Motor Rated Current (FLA)
Terminal S5 Function Selection
Terminal S6 Function Selection
Term MA,MB,MC Function Selection
Motor Overload (oL1) Protection
Optimal Value
0: V/f Control
3.0 s
3.0 s
0: Heavy Duty Rating
7: Overexcitation/High Flux 3
1.40
150
Name
Control Method Selection
Frequency Reference Selection 1
Run Command Selection 1
Acceleration Time 1
Deceleration Time 1
Motor Rated Current (FLA)
Stall Prevention during Decel
OverexcitationBraking (OEB) Gain
HSB Current Suppression Level
12