12.5 d: References
■
d1-08: Reference 8
No.
Name
(Hex.)
d1-08
Reference 8
(0287)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6 [Control Method Selection = AOLV/PM], the drive sets o1-03 = 1 [0.01% (100% = E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 8.
■
d1-09: Reference 9
No.
Name
(Hex.)
d1-09
Reference 9
(0288)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6 [Control Method Selection = AOLV/PM], the drive sets o1-03 = 1 [0.01% (100% = E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 9.
■
d1-10: Reference 10
No.
Name
(Hex.)
d1-10
Reference 10
(028B)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6 [Control Method Selection = AOLV/PM], the drive sets o1-03 = 1 [0.01% (100% = E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 10.
■
d1-11: Reference 11
No.
Name
(Hex.)
d1-11
Reference 11
(028C)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6 [Control Method Selection = AOLV/PM], the drive sets o1-03 = 1 [0.01% (100% = E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 11.
■
d1-12: Reference 12
No.
Name
(Hex.)
d1-12
Reference 12
(028D)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6 [Control Method Selection = AOLV/PM], the drive sets o1-03 = 1 [0.01% (100% = E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 12.
544
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the frequency reference in the units from o1-03 [Frequency Display Unit Selection].
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)