• A1-03 [Initialize Parameters]
• A1-06 [Application Preset]
• A1-07 [DriveWorksEZ Function Selection]
• A2-01 to A2-32 [User Parameter 1 to 32]
Note:
• Usually, the keypad will not show A1-05. To show and set A1-05, show A1-04 [Password] and then push
keypad at the same time.
• After you set A1-05, the keypad will not show it again until you enter the correct password in A1-04. Make sure that you remember the
A1-05 setting value. If you do not know the A1-05 setting value, contact Yaskawa or your nearest sales representative.
• When A1-03 = 2220, 3330 [2-Wire Initialization, 3-Wire Initialization], the drive is initialized to A1-05 = 0000. Be sure to set the
password again when a password is necessary for the application.
• Change the setting value in A1-05 to change the password. The new setting value becomes the new password.
• When you use the password to unlock and change a parameter, enter a value other than the password in A1-04 to lock the parameter
again with the same password.
• If A1-04 ≠ A1-05, MEMOBUS Communication cannot read or write A1-05.
A1-06: Application Preset
WARNING! Sudden Movement Hazard. Check the I/O signals and the external sequences for the drive before you set the
Application Preset function. When you set the Application Preset function (A1-06 ≠ 0), it changes the I/O terminal functions for
the drive and it can cause equipment to operate unusually. This can cause serious injury or death.
No.
Name
(Hex.)
A1-06
Application Preset
(0127)
The drive software contains the application presets shown below. Set A1-06 to align with the application to let the
drive automatically set the best parameter settings for the selected application. The drive saves parameters that
you frequently use the application in parameters A2-01 to A2-16 [User Parameters 1 to 16] for easy configuration
and reference in Setup Mode.
• Water supply pump
• Conveyor
• Exhaust fan
• HVAC fan
• Air compressor
• Crane (hoist)
• Crane (traveling)
Note:
• Before you set A1-06, make sure that you set A1-03 = 2220, 3330 [Initialize Parameters = 2-Wire Initialization, 3-Wire Initialization]
to initialize parameters.
• After you set A1-06 for a hoist application (A1-06 = 6 or 7), make sure that you do Auto-Tuning.
• It is not possible to change the A1-06 value. To set an application preset, first set A1-03 = 2220 to initialize parameters, then set this
parameter. If initializing all parameters will cause a problem, do not change the settings.
If you set A2-33 = 1 [User Parameter Auto Selection = Enabled: Auto Save Recent Parms] to set parameters to A2-17 to A2-32 [User
Parameters 17 to 32] automatically, the drive will reset these parameters when you change the A1-06 setting.
0 : General-purpose
The drive saves the parameters in
Table 12.3 Parameters Saved as User Parameters with the General-purpose Preset
User Parameter No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the drive to operate in selected application conditions.
Table 12.3
as User Parameters.
Parameter No. Saved
A1-02
b1-01
b1-02
b1-03
C1-01
C1-02
C6-01
C6-02
12.2 A: Initialization Parameters
Description
and
on the
Default
(Range)
0
(0 - 8)
Name
Control Method Selection
Frequency Reference Selection 1
Run Command Selection 1
Stopping Method Selection
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
Carrier Frequency Selection
12
461