12.2 A: Initialization Parameters
User Parameter No.
A2-09
A2-10
A2-11
A2-12
A2-13
A2-14
A2-15
A2-16
A2-17
A2-18
A2-19
A2-20
A2-21
A2-22
A2-23
A2-24
A2-25
A2-26
1 : Water Supply Pump 2
The drive automatically sets the parameters in
Table 12.4 Best Parameter Settings for Water Supply Pump Applications
No.
A1-02
b1-04
C1-01
C1-02
C6-01
E1-03
E1-07
E1-08
L2-01
L3-04
The drive saves the parameters in
Table 12.5 Parameters Saved as User Parameters with the Water Supply Pump Preset
User Parameter No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
A2-10
462
Parameter No. Saved
d1-01
d1-02
d1-03
d1-04
d1-17
E1-01
E1-03
E1-04
E1-05
E1-06
E1-09
E1-13
E2-01
E2-04
E2-11
H4-02
L1-01
L3-04
Table 12.4
for a water supply pump application.
Name
Control Method Selection
Reverse Operation Selection
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
V/f Pattern Selection
Mid Point A Frequency
Mid Point A Voltage
Power Loss Ride Through Select
Stall Prevention during Decel
Table 12.5
as User Parameters.
Parameter No. Saved
b1-01
b1-02
b1-04
C1-01
C1-02
E1-03
E1-07
E1-08
E2-01
H1-05
Name
Reference 1
Reference 2
Reference 3
Reference 4
Jog Reference
Input AC Supply Voltage
V/f Pattern Selection
Maximum Output Frequency
Maximum Output Voltage
Base Frequency
Minimum Output Frequency
Base Voltage
Motor Rated Current (FLA)
Motor Pole Count
Motor Rated Power
Terminal AM Analog Output Gain
Motor Overload (oL1) Protection
Stall Prevention during Decel
Optimal Value
0: V/f Control
1: Reverse Disabled
1.0 s
1.0 s
1: Normal Duty Rating
F: Custom
30.0 Hz
50.0 V
1: Enabled for L2-02 Time
1: General Purpose
Name
Frequency Reference Selection 1
Run Command Selection 1
Reverse Operation Selection
Acceleration Time 1
Deceleration Time 1
V/f Pattern Selection
Mid Point A Frequency
Mid Point A Voltage
Motor Rated Current (FLA)
Terminal S5 Function Selection
YASKAWA SIEPC71061753A GA500 Technical Manual