F7-67: PZD8 Write
No.
Name
(Hex.)
F7-67
PZD8 Write
(0787)
F7-68: PZD9 Write
No.
Name
(Hex.)
F7-68
PZD9 Write
(0788)
F7-69: PZD10 Write
No.
Name
(Hex.)
F7-69
PZD10 Write
(0789)
F7-70: PZD1 Read (Status Word)
No.
Name
(Hex.)
F7-70
PZD1 Read (Status Word)
(078A)
F7-71: PZD2 Read (Output Frequency)
No.
Name
(Hex.)
F7-71
PZD2 Read (Output
Frequency)
(078B)
F7-72: PZD3 Read
No.
Name
(Hex.)
F7-72
PZD3 Read
(078C)
F7-73: PZD4 Read
No.
Name
(Hex.)
F7-73
PZD4 Read
(078D)
F7-74: PZD5 Read
No.
Name
(Hex.)
F7-74
PZD5 Read
(078E)
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD8 (PPO output). A value of 0, 1, or 2 will disable
the PZD8 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD9 (PPO output). A value of 0, 1, or 2 will disable
the PZD9 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD10 (PPO output). A value of 0, 1, or 2 will disable
the PZD10 (PPO output) write operation to the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD1 (PPO Read). PZD1 (PPO input) functions as the
ZSW when F7-70 = 0.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD2 (PPO Read). PZD2 (PPO input) functions as the
HIW when F7-71 = 0.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MEMOBUS/Modbus address for PZD3 (PPO Read). A value of 0 will disable the PZD3
(PPO Read) load operation from the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD4 (PPO Read). A value of 0 will disable the PZD4
(PPO Read) load operation from the MEMOBUS/Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MEMOBUS/Modbus address for PZD5 (PPO Read). A value of 0 will disable the PZD5
(PPO Read) load operation from the MEMOBUS/Modbus register.
Description
Description
Description
Description
Description
Description
Description
Description
12.7 F: Options
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
12
597