12.11 o: Keypad-Related Settings
o2-26: Alarm display at ext. 24V power
No.
Name
(Hex.)
o2-26
Alarm display at ext. 24V
power
(1563)
0 : Disabled
The drive will not detect EP24v [External Power 24V Supply] if the main circuit power supply voltage decreases.
The [Ready] light on the LED Status Ring flashes quickly to identify that drive operation is not possible.
1 : Enabled
The drive detects EP24v when the main circuit power supply voltage decreases.
Note:
The minor fault signal is not output from H2-xx = 10 [MFDO Function Selection = Alarm].
o2-27: bCE Detection Selection
No.
Name
(Hex.)
o2-27
bCE Detection Selection
(1565)
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display

o3: Copy Function

o3 parameters set the operation of the parameter backup function.
o3-01: Copy Keypad Function Selection
No.
Name
(Hex.)
o3-01
Copy Keypad Function
Selection
(0515)
0 : Copy Select
1 : Backup (drive → keypad)
The parameter setting values are read from the drive and saved in the keypad.
2 : Restore (keypad → drive)
Copies the parameter setting values saved in the keypad to a different drive.
3 : Verify (check for mismatch)
Makes sure that the parameter setting values in the drive agree with the parameters saved in the keypad.
4 : Erase (backup data of keypad)
Deletes the parameter setting values saved in the keypad.
o3-02: Copy Allowed Selection
No.
Name
(Hex.)
o3-02
Copy Allowed Selection
(0516)
Note:
When you select [Parameter Backup] on the keypad menu screen to do the backup function, the drive automatically sets o3-02 = 1.
0 : Disabled
740
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
When you connect a backup external 24 V power supply, this parameter sets the function to
trigger an alarm when the main circuit power supply voltage decreases.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets drive operation if the Bluetooth device is disconnected when you operate the drive in
Bluetooth Mode.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that saves and copies drive parameters to a different drive with the keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection = Backup (drive →
keypad)].
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
0
(0, 1)
Default
(Range)
3
(0 - 4)
Default
(Range)
0
(0 - 4)
Default
(Range)
0
(0, 1)