12.8 H: Terminal Function Selection
■
61: Pole Position Detection Complete
Setting Value
Function
61
Pole Position Detection
Complete
■
62: Modbus Reg 1 Status Satisfied
Setting Value
Function
62
Modbus Reg 1 Status
Satisfied
■
63: Modbus Reg 2 Status Satisfied
Setting Value
Function
63
Modbus Reg 2 Status
Satisfied
■
66: Comparator1
Setting Value
Function
66
Comparator1
A - H2-24
[Comparator 1 On-Delay Time]
Note:
The drive compares the monitors set with H2-20 as absolute values.
■
67: Comparator2
Setting Value
Function
67
Comparator2
640
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when drive receives a Run command and the drive detects the motor magnetic pole position of the PM
motor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the bit specified by H2-08 [Modbus Register 1 Bit Select] for the MEMOBUS register address set
with H2-07 [Modbus Register 1 Address Select] activates.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the bit specified by H2-10 [Modbus Register 2 Bit Select] for the MEMOBUS register address set
with H2-09 [Modbus Register 2 Address Select] activates.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates if the monitor value set with H2-20 [Comparator 1 Monitor Selection] is in range of the values of H2-21
[Comparator 1 Lower Limit] and H2-22 [Comparator 1 Upper Limit] for the time set in H2-24 [Comparator 1 On-Delay
Time].
Figure 12.88 Comparator 1 Output Time Chart
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates if the monitor value set with H2-26 [Comparator 2 Monitor Selection] is not in the range of the values of
H2-27 [Comparator 2 Lower Limit] and H2-28 [Comparator 2 Upper Limit] for the time set in H2-30 [Comparator 2 On-
Delay Time].
Description
Description
Description
Description
B - H2-25
[Comparator 1 Off-Delay Time]
Description
YASKAWA SIEPC71061753A GA500 Technical Manual