YASKAWA CIPR-GA50C series Technical Manual page 662

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.8 H: Terminal Function Selection
Note:
• Refer to H1-xx "MFDI Setting Values" for more information on the virtual digital input setting values.
• Refer to H2-xx "MFDO Setting Values" for more information on the virtual digital output setting values.
• Refer to H3-xx "MFAI Setting Values" for more information on the virtual analog input setting values.
• Refer to H4-xx "MFAO Setting Values" for more information on the virtual analog output setting values.
• You cannot set 0 [3-Wire Sequence] and 20 or 2F [External Fault] to H7-01 to H7-04 [Virtual Multi-Function Input 1 to 4].
• If the terminal is not used, set H7-01 to H7-04 = F. However, the through mode function is not supported.
H7-00: Virtual MFIO selection
No.
Name
(Hex.)
H7-00
Virtual MFIO selection
(116F)
Expert
0 : Disabled
1 : Enabled
H7-01: Virtual Multi-Function Input 1
No.
Name
(Hex.)
H7-01
Virtual Multi-Function
Input 1
(1185)
Expert
H7-02: Virtual Multi-Function Input 2
No.
Name
(Hex.)
H7-02
Virtual Multi-Function
Input 2
(1186)
Expert
H7-03: Virtual Multi-Function Input 3
No.
Name
(Hex.)
H7-03
Virtual Multi-Function
Input 3
(1187)
Expert
H7-04: Virtual Multi-Function Input 4
No.
Name
(Hex.)
H7-04
Virtual Multi-Function
Input 4
(1188)
Expert
H7-10: Virtual Multi-Function Output 1
No.
Name
(Hex.)
H7-10
Virtual Multi-Function
Output 1
(11A4)
Expert
H7-11: Virtual Output 1 Delay Time
No.
Name
(Hex.)
H7-11
Virtual Output 1 Delay
Time
(11A5)
Expert
662
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to operate
the virtual I/O function.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function that enters the virtual input set in H7-10 [Virtual Multi-Function Output 1].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that enters the virtual input set in H7-12 [Virtual Multi-Function Output 2].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that enters the virtual input set in H7-14 [Virtual Multi-Function Output 3].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function that enters the virtual input set in H7-16 [Virtual Multi-Function Output 4].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for virtual digital output 1.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum ON time for virtual digital output 1.
Description
Description
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
0
(0, 1)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(1 - 19F)
Default
(Range)
F
(0 - 1A7)
Default
(Range)
0.1 s
(0.0 - 25.0 s)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents