11.10 H: Terminal Functions
No.
Name
(Hex.)
H2-66
Terminal P2 Secondary
Function
(1B4C)
Expert
H2-67
Terminal P2 Logical
Operation
(1B4D)
Expert
H2-68
Terminal P2 Minimum
ON Time
(1B4E)
Expert
H2-xx: MFDO Setting Values
Setting Value
Function
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-Set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive ready
376
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the second function for terminal P2-C2. Outputs the logical calculation results of
the terminals assigned to functions by H2-03 [Term P2 Function Selection].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the logical operation for the functions set in H2-03 [Term P2 Function Selection]
and H2-66 [Terminal P2 Secondary Function].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the minimum ON time used to output the logical calculation results from terminal
P2-C2.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the Run command is input and when the drive is outputting voltage.
ON : Drive is running
OFF : Drive is stopping
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the output frequency is less than the value of E1-09 [Minimum Output Frequency] or
b2-01 [DC Injection/Zero SpeedThreshold].
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the reference.
A1-02 Setting
Control Method Selection
0
V/f
2
OLV
5
OLV/PM
6
AOLV/PM
8
EZOLV
ON : Output frequency < value of E1-09 or b2-01.
OFF : Output frequency ≥ value of E1-09 or b2-01.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the output frequency is in the range of the frequency reference ± L4-02 [Speed Agree
Detection Width].
ON : The output frequency is in the range of "frequency reference ± L4-02".
OFF : The output frequency does not align with the frequency reference although the drive is running.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the output frequency is in the range of L4-01 [Speed Agree Detection Level] ± L4-02
[Speed Agree Detection Width] and in the range of the frequency reference ± L4-02.
Note:
The detection function operates in the two motor rotation directions. The drive uses the L4-01 value as the
forward/reverse detection level.
ON : The output frequency is within the range as defined by the result of "L4-01 ± L4-02" and the range of
frequency reference ± L4-02.
OFF : The output frequency is not in the range of "L4-01 ± L4-02" nor the range of frequency reference ± L4-02.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal deactivates when the output frequency is higher than the value of L4-01 [Speed Agree Detection
Level] + L4-02 [Speed Agree Detection Width]. After the terminal turns off, the terminal continues to remain off
until the output frequency reaches the level set with L4-01.
Note:
The detection function operates in the two motor rotation directions. The drive uses the L4-01 value as the
forward/reverse detection level.
ON : The output frequency is less than the value of L4-01 or does not exceed the value of L4-01 + L4-02.
OFF : The output frequency is higher than the value of L4-01 + L4-02.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the output frequency is higher than the value of L4-01 [Speed Agree Detection Level].
After the terminal activates, the terminal stays activated until the output frequency is at the value of L4-01 - L4-02.
Note:
The detection function operates in the two motor rotation directions. The drive uses the L4-01 value as the
forward/reverse detection level.
ON : The output frequency is higher than the value of L4-01.
OFF : The output frequency is less than the value of "L4-01 - L4-02," or it does not exceed the value of L4-01.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the drive is ready and running.
Description
Parameter Used as the Reference
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
Ref.
(Range)
F
628
(0 - FF)
0
628
(0 - 8)
0.1 s
628
(0.0 - 25.0 s)
Ref.
629
629
E1-09
b2-01
E1-09
E1-09
E1-09
629
630
630
631
631

Advertisement