YASKAWA CIPR-GA50C series Technical Manual page 746

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.11 o: Keypad-Related Settings
No.
Item
7
Drive capacity
8
Sampling time
(maximum)
9
Row number
*1
If you do not set the time in the keypad, the text string of [000000000000] is generated to show the time.
Second Row: Log Data Information
This example shows the data text strings and data generated for the second row of log data.
Example of generated data:
01,0012,160107111230,0101,0201,0102,0201,0103,0206,0107,0005,0108,0209,0000,0000,0000,0000,0000,0
000,0000,0000,0000,0000,0000,0000,0000,0000,000002
No.
Item
1
Attribute
2
File number
3
Time stamp
*1
4
Monitor Number 1
*2
5
Monitor Unit 1
6
Monitor number 2
7
Monitor Unit 2
:
:
22
Monitor number 10
23
Monitor Unit 10
24 - 27
Reserved
28
Row number
*1
If there is no data log monitor selected, the text string of [0000] is generated.
*2
Refer to
Table 12.75
for information about unit codes.
Unit Code (Hex.)
Unit
00
01
Hz
02
RPM
03
%
04
VAC
05
VDC
06
A
07
sec
Third and Subsequent Rows: Log Data
This example shows the data text strings and data generated for the third row of log data.
Example of generated data:
02,0012,160107111239,1770,1770,00BE,0118,0028,0000,0000,0000,0000,0000,0000,0000,00000C
No.
Item
1
Attribute
2
File number
746
Number
of
Example
Charac
ters
2
62
5
1000
6
000001
Number of
Characters
2
[01] shows that the record is a log data information record.
4
Generates the [xxx] part (a 3-digit decimal number) of the [GLOG0xxx.csv] filename of the log data in hexadecimal
format.
12
Date file was generated
4
Monitor number selected by o5-03 [Log Monitor Data 1]
Ex.: 0101 (Dec.) for U1-01
4
Unit code and number of decimal places used for the monitor selected with o5-03
Example when U1-01 = 30.00 Hz:
Number of decimal places = 2, Hz unit code = 01, monitor unit 1 = 0201 (Hex.)
4
Monitor number (Dec.) selected by o5-04 [Log Monitor Data 2]
4
Unit code and number of decimal places used for the monitor selected with o5-04
:
:
4
Monitor number (Dec.) selected by o5-12 [Log Monitor Data10]
4
Unit code and number of decimal places used for the monitor selected with o5-12
4
-
6
Row number (Hex.) in the data log file
Table 12.75 Unit Codes
Unit Code (Hex.)
08
09
0A
0B
0C
0D
0E
0F
Number of
Characters
2
[02] shows that the record is a monitor data record.
4
Generates the [xxx] part (a 3-digit decimal number) of the [GLOG0xxx.csv] filename of the log data in hexadecimal
format.
Setting value (Hex.) of o2-04 [Drive Model (KVA) Selection]
Setting value (Dec.) of o5-02 [Log Sampling Interval]
Unit: ms
Row number (Hex.) in the data log file
Description
Unit
Unit Code (Hex.)
PPR
10
kW
11
Ω
12
ms
13
kHz
14
PSI
15
MPM
16
FPM
17
Description
Description
Unit
Unit Code (Hex.)
H
18
V
19
us
1A
min
1B
°C
1C
W
1D
kWH
1E
MWH
1F
YASKAWA SIEPC71061753A GA500 Technical Manual
Unit
0H

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents