O2: Keypad Operation - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.11 o: Keypad-Related Settings
o1-51: Trend Plot Time Scale Setting
No.
Name
(Hex.)
o1-51
Trend Plot Time Scale
Setting
(11CB)
RUN
o1-55: Analog Gauge Area Selection
No.
Name
(Hex.)
o1-55
Analog Gauge Area
Selection
(11EE)
RUN
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
o1-56: Analog Gauge Area Setting
No.
Name
(Hex.)
o1-56
Analog Gauge Area Setting
(11EF)
RUN
o1-58: Motor Power Unit Selection
No.
Name
(Hex.)
o1-58
Motor Power Unit Selection
(3125)
The drive shows these parameter values in the set units:
• E2-11 [Motor Rated Power]
• E4-11 [Motor 2 Rated Power]
• E5-02 [PM Motor Rated Power]
• E9-07 [Motor Rated Power]
• T1-02 [Motor Rated Power]
• T2-04 [PM Motor Rated Power]
• T4-08 [Motor Rated Capacity]
0 : kW
Shows the motor output in kW units.
1 : HP
Shows the motor output in HP units.

o2: Keypad Operation

o2-01: LO/RE Key Function Selection
No.
Name
(Hex.)
o2-01
LO/RE Key Function
Selection
(0505)
0 : Disabled
You cannot use
to switch between LOCAL and REMOTE Modes.
1 : Enabled
736
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the
drive automatically adjusts the data sampling time. This parameter is only available when using
an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge.
This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog meter.
This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the setting unit for parameters that set the motor rated power.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that lets you use
Description
Description
Description
Description
Description
to switch between LOCAL and REMOTE Modes.
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
300 s
(1 - 3600 s)
Default
(Range)
1
(0, 1)
Default
(Range)
100.0%
(0.0 - 100.0%)
Default
(Range)
0
(0, 1)
Default
(Range)
1
(0, 1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents