12.11 o: Keypad-Related Settings
■
o1-51: Trend Plot Time Scale Setting
No.
Name
(Hex.)
o1-51
Trend Plot Time Scale
Setting
(11CB)
RUN
■
o1-55: Analog Gauge Area Selection
No.
Name
(Hex.)
o1-55
Analog Gauge Area
Selection
(11EE)
RUN
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
■
o1-56: Analog Gauge Area Setting
No.
Name
(Hex.)
o1-56
Analog Gauge Area Setting
(11EF)
RUN
■
o1-58: Motor Power Unit Selection
No.
Name
(Hex.)
o1-58
Motor Power Unit Selection
(3125)
The drive shows these parameter values in the set units:
• E2-11 [Motor Rated Power]
• E4-11 [Motor 2 Rated Power]
• E5-02 [PM Motor Rated Power]
• E9-07 [Motor Rated Power]
• T1-02 [Motor Rated Power]
• T2-04 [PM Motor Rated Power]
• T4-08 [Motor Rated Capacity]
0 : kW
Shows the motor output in kW units.
1 : HP
Shows the motor output in HP units.
◆
o2: Keypad Operation
■
o2-01: LO/RE Key Function Selection
No.
Name
(Hex.)
o2-01
LO/RE Key Function
Selection
(0505)
0 : Disabled
You cannot use
to switch between LOCAL and REMOTE Modes.
1 : Enabled
736
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the
drive automatically adjusts the data sampling time. This parameter is only available when using
an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge.
This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog meter.
This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the setting unit for parameters that set the motor rated power.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that lets you use
Description
Description
Description
Description
Description
to switch between LOCAL and REMOTE Modes.
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
300 s
(1 - 3600 s)
Default
(Range)
1
(0, 1)
Default
(Range)
100.0%
(0.0 - 100.0%)
Default
(Range)
0
(0, 1)
Default
(Range)
1