YASKAWA CIPR-GA50C series Technical Manual page 600

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.8 H: Terminal Function Selection
Setting Value
67
Communications Test Mode
68
High Slip Braking (HSB)
6A
Drive Enable
75
Up 2 Command
76
Down 2 Command
77
ASR Gain (C5-03) Select
*1
7A
KEB Ride-Thru 2 Activate (N.C.)
*1
7B
KEB Ride-Thru 2 Activate (N.O.)
*1
7C
Short Circuit Braking (N.O.)
*1
Inverse input is not available.
*2
You cannot use H7-01 to H7-04 [Virtual Multi-Function Input 1 to 4] to set this.
H1-01: Terminal S1 Function Selection
No.
Name
(Hex.)
H1-01
Terminal S1 Function
Selection
(0438)
Note:
The default setting is F when the drive is initialized for 3-Wire Initialization [A1-03 = 3330].
H1-02: Terminal S2 Function Selection
No.
Name
(Hex.)
H1-02
Terminal S2 Function
Selection
(0439)
Note:
The default setting is F when the drive is initialized for 3-Wire Initialization [A1-03 = 3330].
H1-03: Terminal S3 Function Selection
No.
Name
(Hex.)
H1-03
Terminal S3 Function
Selection
(0400)
H1-04: Terminal S4 Function Selection
No.
Name
(Hex.)
H1-04
Terminal S4 Function
Selection
(0401)
H1-05: Terminal S5 Function Selection
No.
Name
(Hex.)
H1-05
Terminal S5 Function
Selection
(0402)
Note:
When you initialize the drive for 3-Wire Initialization [A1-03 = 3330], the default setting is 0.
H1-06: Terminal S6 Function Selection
No.
Name
(Hex.)
H1-06
Terminal S6 Function
Selection
(0403)
600
Function
Reference
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for MFDI terminal S1.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for MFDI terminal S2.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for MFDI terminal S3.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for MFDI terminal S4.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for MFDI terminal S5.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for MFDI terminal S6.
Setting Value
*1
7D
Short Circuit Braking (N.C.)
616
7E
Reverse Rotation Identifier
616
7F
PID Bi-Directional Enable
616
*1
616
90 to 96
DWEZ Digital Inputs 1 to 7
9F
DWEZ Disable
618
101 to 19F
Inverse Input of 1 to 9F
618
Sets the function of the selected MFDI to operate
618
inversely. To select the function for inverse input,
enter two digits 01 to 9F for the "xx" in "1xx".
618
618
Description
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Function
Reference
Default
(Range)
40
(1 - 1FF)
Default
(Range)
41
(1 - 1FF)
Default
(Range)
24
(0 - 1FF)
Default
(Range)
14
(0 - 1FF)
Default
(Range)
3
(0 - 1FF)
Default
(Range)
4
(0 - 1FF)
619
619
619
619
619
620

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents