4.2 Keypad: Names and Functions
Symbol
Name
RUN LED
G
Left Arrow Key
Up Arrow Key/Down
Arrow Key
/
H
Right Arrow Key (RESET) • Moves the cursor to the right.
ENTER Key
ESC Key
I
J
LED Display
LO/RE Selection Key
K
REV LED
L
DWEZ LED
M
N
RJ-45 Connector
WARNING! Sudden Movement Hazard. If you change the control source when b1-07 = 1 [LOCAL/REMOTE Run Selection =
Accept Existing RUN Command], the drive can start suddenly. Before you change the control source, remove all personnel from
the area around the drive, motor, and load. Sudden starts can cause serious injury or death.

Indicator flashing statuses

for the difference between "flashing" and "flashing quickly".
Refer to
Figure 4.2
114
Illuminated: The drive is in regular operation.
OFF: The drive is stopped.
Flashing:
• The drive is decelerating to stop.
• The drive received a Run command, but the frequency reference is 0 Hz.
Flashing quickly:
• The drive received a Run command from the MFDI terminals and is switching to REMOTE Mode while the drive is in LOCAL
Mode.
• The drive received a Run command from the MFDI terminals when the drive is not in Drive Mode.
• The drive received a Fast Stop command.
• The safety function shuts off the drive output.
• The user pushed
on the keypad while the drive is operating in REMOTE Mode.
• The drive is energized with an active Run command and b1-17 = 0 [Run Command at Power Up = Disregard Existing RUN
Command].
Moves the cursor to the left.
• Moves to a different screen.
• Selects parameter numbers and increments or decrements setting values.
• Restarts the drive to clear a fault.
• Enters parameter values and settings.
• Selects each mode, parameter, and set value.
• Goes back to the previous screen.
• Push and hold to go back to the frequency reference screen (the initial screen).
Shows parameters, errors, and other data.
Switches drive control for the Run command and frequency reference between the keypad (LOCAL) and an external source
(REMOTE).
Note:
• The LOCAL/REMOTE Selection Key continuously stays enabled after the drive stops in Drive Mode. If the application must not
switch from REMOTE to LOCAL because it will have a negative effect on system performance, set o2-01 = 0 [LO/RE Key
Function Selection = Disabled] to disable
• The drive will not switch between LOCAL and REMOTE when it is receiving a Run command from an external source.
Illuminated: The drive received a Reverse run command.
Illuminated: The drive is In DriveWorksEZ operation.
Connects to the drive. Use an RJ-45 8-pin straight through UTP CAT5e extension cable to install the keypad in a different location than
the drive.
Figure 4.2 About indicator flashing statuses
Function
.
YASKAWA SIEPC71061753A GA500 Technical Manual