T3: Asr And Inertia Tuning; T4: Ez Tuning - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

11.16 T: Motor Tuning
No.
Name
(Hex.)
T2-14
Back-EMF Voltage
Constant (Ke)
(0737)
T2-15
Pull-In Current Level
(0756)

T3: ASR and Inertia Tuning

No.
Name
(Hex.)
T3-00
Control Loop Tuning
Selection
(1198)

T4: EZ Tuning

No.
Name
(Hex.)
T4-01
EZ Tuning Mode
Selection
(3130)
T4-02
Motor Type Selection
(3131)
T4-04
Motor Rated Revolutions
(3133)
T4-05
Motor Rated Frequency
(3134)
T4-06
Motor Rated Voltage
(3135)
T4-07
Motor Rated Current
(3136)
T4-08
Motor Rated Capacity
(3137)
T4-09
Number of Poles
(3138)
412
Description
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the motor induced voltage constant (Ke).
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the level of the pull-in current as a percentage of E5-03 [PM Motor Rated Current
(FLA)]. Usually it is not necessary to change this setting.
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the type of Control Auto-Tuning.
2 : Deceleration Rate Tuning
3 : KEB Tuning
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the type of Auto-Tuning for EZOLV control.
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets rated rotation speed (min
-1
) of the motor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the rated frequency (Hz) of the motor.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the rated voltage (V) of the motor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the rated current (A) of the motor.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the motor rated power in the units set in o1-58 [Motor Power Unit Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the number of motor poles.
Default
(Range)
Determined by T2-13
(0.0 - 2000.0)
30%
(0 - 120%)
Default
(Range)
2
(2, 3)
Default
(Range)
0
(0, 1)
0
(0, 1, 2)
-
((40 Hz to 120 Hz) × 60
× 2/E9-08)
Determined by E9-01
and o2-04
(40.0 - 120.0 Hz)
200 V Class: 200.0 V,
400 V: 400.0 V
(200 V Class: 0.0 - 255.0
V,400 V Class: 0.0 -
510.0 V)
Determined by o2-04,
C6-01
(10% to 200% of the
drive rated current)
Determined by E9-10
(0.10 - 650.00 kW)
Determined by E9-01
(2 - 48)
YASKAWA SIEPC71061753A GA500 Technical Manual
Ref.
755
755
Ref.
755
Ref.
755
756
756
756
756
756
756
756

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents