12.10 n: Special Adjustment
n8-76: Id Switching Filter Time
No.
Name
(Hex.)
n8-76
Id Switching Filter Time
(05CD)
Expert
n8-77: Heavy Load Iq Level
No.
Name
(Hex.)
n8-77
Heavy Load Iq Level
(05CE)
Expert
Note:
The change is linear between n8-75 [Medium Load Iq Level (low)] and n8-77 and the level of the pull-in current from n8-78 [Medium
Load Id Current] to n8-49 [Heavy Load Id Current].
n8-78: Medium Load Id Current
No.
Name
(Hex.)
n8-78
Medium Load Id Current
(05F4)
RUN
Expert
n8-79: Pull-in Current @ Deceleration
No.
Name
(Hex.)
n8-79
Pull-in Current @
Deceleration
(05FE)
If overcurrent occurs during deceleration, slowly decrease the setting in 5% increments.
Note:
When n8-79 = 0, the drive will use the value set in n8-51 [Pull-in Current @ Acceleration].
n8-84: Polarity Detection Current
No.
Name
(Hex.)
n8-84
Polarity Detection Current
(02D3)
Expert
WARNING! Sudden Movement Hazard. Make sure that the polarity is correct before you send a Run command. If the drive
incorrectly detects the polarity, the drive can rotate in the direction opposite of the Run command and cause serious injury or
death.
When you use a Yaskawa motor, check the motor nameplate for an "Si" value and set this parameter ≥ "Si × 2".
Consult the motor manufacturer for information about maximum setting values.
Find the Polarity of Magnetic Poles
When you start operation, the drive estimates the magnetic poles and finds the polarity of the magnetic poles.
Use U6-57 [PolePolarityDeterVal] to make sure that the magnetic pole estimate was correct.
When you do High Frequency Injection Auto-Tuning, the drive automatically sets n8-84.
n8-87: Output Voltage Limit Selection
No.
Name
(Hex.)
n8-87
Output Voltage Limit
Method
(02BC)
726
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the filter time constant for the d-axis current reference. Usually it is not necessary to change
this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Set n8-49 [Heavy Load Id Current] to the percentage of load current (q-axis current) that you will
apply, where E5-03 [Motor Rated Current (FLA)] = a setting value of 100%.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the level of the pull-in current as a percentage, where E5-03 [PM Motor Rated Current
(FLA)] = 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the pull-in current that can flow during deceleration as a percentage of the E5-03 [PM Motor
Rated Current (FLA)].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the current that the drive uses to estimate the initial motor magnetic pole as a percentage
where E5-03 [PM Motor Rated Current (FLA)] = 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the method of output voltage limit. If there is vibration in the constant output range, set
Feedforward Method. Usually it is not necessary to change this setting.
Description
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
200 ms
(0 - 5000)
Default
(Range)
90%
(0 - 255%)
Default
(Range)
0%
(0 - 255%)
Default
(Range)
50%
(0 - 200%)
Default
(Range)
100%
(0 - 150%)
Default
(Range)
0
(0, 1)