12.8 H: Terminal Function Selection
Note:
The terminal deactivates in these conditions:
• During Stop
• During baseblock
• During DC Injection Braking (initial excitation)
• During Short Circuit Braking
■
38: Drive Enabled
Setting Value
Function
38
Drive Enabled
■
39: Watt Hour Pulse Output
Setting Value
Function
39
Watt Hour Pulse Output
Note:
Refer to "H2-06: Watt Hour Output Unit Selection" for more information.
■
3C: LOCAL Control Selected
Setting Value
Function
3C
LOCAL Control Selected
ON : LOCAL
The keypad is the Run command source or the frequency reference source.
OFF : REMOTE
The Run command source or frequency reference source is an external source set with b1-01 [Frequency
Reference Selection 1], b1-15 [Frequency Reference Selection 2], b1-02 [Run Command Selection 1], or b1-16
[Run Command Selection 2].
■
3D: During Speed Search
Setting Value
Function
3D
During Speed Search
Note:
Refer to "b3: Speed Search" for more information.
■
3E: PID Feedback Low
Setting Value
Function
3E
PID Feedback Low
The drive detects FbL [PID Feedback Loss] when the PID feedback value < b5-13 [PID Feedback Loss Detection
Lvl] for longer than the time set in b5-14 [PID Feedback Loss Detection Time].
638
Figure 12.87 Active Frequency Output Time Chart
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
This terminal activates when the H1-xx = 6A [Drive Enable] terminal activates.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Outputs the pulse that shows the watt hours.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the Run command source or frequency reference source is LOCAL.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the drive is doing speed search.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the drive detects FbL [PID Feedback Loss].
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual