YASKAWA CIPR-GA50C series Technical Manual page 623

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

Note:
• When the power value is a negative value (regenerative state), the drive does not count Watt hours.
• When the control power supply to the drive is operating, the drive will keep the Watt hours. If a momentary power loss causes the drive
to lose control power, the Watt hour count will reset.
0 : 0.1 kWh units
1 : 1 kWh units
2 : 10 kWh units
3 : 100 kWh units
4 : 1000 kWh units
H2-07: Modbus Register 1 Address Select
No.
Name
(Hex.)
H2-07
Modbus Register 1 Address
Select
(0B3A)
Sets the address of the register that is output to Modbus Reg 1 Status Satisfied [H2-01 to H2-03 = 62] and uses the
bit in H2-08 [Modbus Register 1 Bit Select].
H2-08: Modbus Register 1 Bit Select
No.
Name
(Hex.)
H2-08
Modbus Register 1 Bit
Select
(0B3B)
Sets the bit of the register that is output to Modbus Reg 1 Status Satisfied [H2-01 to H2-03 = 62] and uses the
address in H2-07 [Modbus Register 1 Address Select].
H2-09: Modbus Register 2 Address Select
No.
Name
(Hex.)
H2-09
Modbus Register 2 Address
Select
(0B3C)
Sets the address of the register that is output to Modbus Reg 2 Status Satisfied [H2-01 to H2-03 = 63] and uses the
bit in H2-10 [Modbus Register 2 Bit Select].
H2-10: Modbus Register 2 Bit Select
No.
Name
(Hex.)
H2-10
Modbus Register 2 Bit
Select
(0B3D)
Sets the bit of the register that is output to Modbus Reg 2 Status Satisfied [H2-01 to H2-03 = 63] and uses the
address in H2-09 [Modbus Register 2 Address Select].
YASKAWA SIEPC71061753A GA500 Technical Manual
Figure 12.75 Example MFDO when Configured for Watt Hours
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
12.8 H: Terminal Function Selection
Description
Description
Description
Description
Default
(Range)
0001
(0001 - 1FFF)
Default
(Range)
0000
(0000 - FFFF)
Default
(Range)
0001
(0001 - 1FFF)
Default
(Range)
0000
(0000 - FFFF)
12
623