2.5 Drive Models and Drive Watt Loss
Rated output current
Model
4007E
4009E
4012E
4018E
4023E
4031E
4038E
4044E
4060E
Rated output current
Model
4001E
4002E
4004E
4005E
4007E
4009E
4012E
4018E
4023E
4031E
4038E
4044E
4060E
38
Carrier Frequency
A
kHz
5.6
8
7.3
8
9.2
8
14.8
8
18
8
24
8
31
8
39
8
45
8
Table 2.17 Drive Watt Loss (ND)
Carrier Frequency
A
kHz
1.2
2
2.1
2
4.1
2
5.4
2
7.1
2
8.9
2
11.9
2
17.5
2
23.4
2
31
2
38
2
44
2
60
2
Interior Unit Loss
Cooling Fin Loss
W
20
28
34
59
65
84
103
137
149
Interior Unit Loss
Cooling Fin Loss
W
9
14
16
18
23
33
41
56
94
109
119
151
200
YASKAWA SIEPC71061753A GA500 Technical Manual
Total Loss
W
W
49
69
65
93
85
119
166
225
200
265
255
339
338
441
442
579
446
595
Total Loss
W
W
7
16
12
26
24
40
32
50
44
67
58
91
83
124
155
211
236
330
284
393
341
460
417
568
490
690