Register No.
(Hex.)
Drive rated current
Note:
00AB
The unit of display is different for different models.
2001 to 2042, B001 to B018, 4001 to 4023: 0.01 A
2056 to 2082, 4031 to 4060: 0.1 A
00AC
U1-05 [Motor Speed]
00AD
00AE, 00AF
Reserved
Option codes connected to
00B0
CN5
00B1 - 00B4
Reserved
00B5
U1-16 [SFS Output
Frequency]
00B6
00B7
Frequency reference
monitor
00B8
00B9 - 00BE
Reserved
Operation error number
00BF
xx of oPExx is displayed.
Fault Description 3
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
00C0
bit 7
bit 8
bit 9
bit A
bit B
bit C
bit D
bit E
bit F
YASKAWA SIEPC71061753A GA500 Technical Manual
Units: min
-1
or r/min
Note:
Set E2-04, E4-04, E5-04, E9-08 [Motor Pole Count].
Units: 0.01%
The drive stores option codes in the register.
SI-C3 = 5343 (Hex.)
SI-EM3 = 1005 (Hex.)
SI-EN3 = 1006 (Hex.)
SI-EP3 = 1007 (Hex.)
SI-ES3 = 1001 (Hex.)
SI-ET3 = 1004 (Hex.)
SI-N3 = 534E (Hex.)
SI-P3 = 5350 (Hex.)
SI-S3 = 5353 (Hex.)
SI-T3 = 5354 (Hex.)
Units: min
-1
or r/min
Note:
Set E2-04, E4-04, E5-04, E9-08 [Motor Pole Count].
Units: 0.01%
Units: min
-1
or r/min
Note:
Set E2-04, E4-04, E5-04, E9-08 [Motor Pole Count].
Units: 0.01%
Reserved
Uv1 [DC Bus Undervoltage]
Uv2 [Control Power Undervoltage]
Uv3 [Soft Charge Answerback Fault]
SC [Short Circuit/IGBT Failure]
GF [Ground Fault]
oC [Overcurrent]
ov [Overvoltage]
oH [Heatsink Overheat]
oH1 [Heatsink Overheat]
oL1 [Motor Overload]
oL2 [Drive Overload]
oL3 [Overtorque Detection 1]
oL4 [Overtorque Detection 2]
rr [Dynamic Braking Transistor Fault]
rH [Braking Resistor Overheat]