12.8 H: Terminal Function Selection
■
1A: During Reverse
Setting Value
Function
1A
During reverse
ON : The motor is operating in the reverse direction.
OFF : The motor is operating in the forward direction or the motor stopped.
■
1B: During Baseblock (N.C.)
Setting Value
Function
1B
During Baseblock (N.C.)
ON : The drive is not in baseblock.
OFF : During baseblock
■
1C: Motor 2 Selected
Setting Value
Function
1C
Motor 2 Selected
ON : Motor 2 Selection
OFF : Motor 1 Selection
■
1E: Executing Auto-Restart
Setting Value
Function
1E
Executing Auto-Restart
The terminal deactivates when the Auto Restart function automatically resets a fault. The terminal turns off when
the Auto Restart function detects the fault again since Auto Restart function cannot function any longer due to
number of attempts set with L5-01 [Number of Auto Restart Attempts] being reached.
Note:
Refer to "L5: Auto-Restart" for more information.
■
1F: Motor Overload Alarm (oL1)
Setting Value
Function
1F
Motor Overload Alarm
(oL1)
Note:
Refer to "L1-01: Motor Overload (oL1) Protection" for more information.
636
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the motor operates in the reverse direction.
Figure 12.86 Reverse Operation Output Time Chart
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal deactivates during baseblock. When the drive is in baseblock, the drive output transistor stops switching and does
not make DC bus voltage.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when motor 2 is selected.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the Auto Restart function is trying to restart after a fault.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the electronic thermal protection value of the motor overload protective function is a minimum of
90% of the detection level.
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual