YASKAWA CIPR-GA50C series Technical Manual page 375

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

No.
Name
(Hex.)
H2-27
Comparator 2 Lower
Limit
(1547)
H2-28
Comparator 2 Upper
Limit
(1548)
H2-29
Comparator 2 Hysteresis
(1549)
H2-30
Comparator 2 On-Delay
Time
(154A)
H2-31
Comparator 2 Off-Delay
Time
(154B)
H2-32
Comparator 1 Filter
Time
(159A)
H2-33
Comparator1 Protection
Selection
(159B)
H2-34
Comparator 2 Filter
Time
(159C)
H2-35
Comparator2 Protection
Selection
(159D)
H2-36
Comparator 1 Ineffective
Time
(159E)
H2-37
Comparator 2 Ineffective
Time
(159F)
H2-40
Mbus Reg 15E0h bit0
Output Func
(0B58)
H2-41
Mbus Reg 15E0h bit1
Output Func
(0B59)
H2-42
Mbus Reg 15E0h bit2
Output Func
(0B5A)
H2-60
Term MA,MB,MC
Secondary Function
(1B46)
Expert
H2-61
Term MA,MB,MC
Logical Operation
(1B47)
Expert
H2-62
Term MA,MB,MC
Minimum ON Time
(1B48)
Expert
H2-63
Terminal P1 Secondary
Function
(1B49)
Expert
H2-64
Terminal P1 Logical
Operation
(1B4A)
Expert
H2-65
Terminal P1 Minimum
ON Time
(1B4B)
Expert
YASKAWA SIEPC71061753A GA500 Technical Manual
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the lower limit detection level for comparator 2 as a percentage of the full scale
analog output for the monitor selected in H2-26 [Comparator 2 Monitor Selection].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the upper limit detection level for comparator 2 as a percentage of the full scale
analog output for the monitor selected in H2-26 [Comparator 2 Monitor Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the hysteresis level for comparator 2 as a percentage of the full scale analog output
for the monitor selected in H2-26 [Comparator 2 Monitor Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the on-delay time for comparator 2.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the off-delay time for comparator 2.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the time constant that is applied to the primary delay filter used for the analog
output of the monitor selected with H2-20 [Comparator 1 Monitor Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets drive operation when it detects CP1 [Comparator1 Limit Fault].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Digital Output Only
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the time constant that is applied to the primary delay filter used for the analog
output of the monitor selected with H2-26 [Comparator 2 Monitor Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets drive operation when it detects CP2 [Comparator2 Limit Fault].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Digital Output Only
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the length of time that CP1 [Comparator1 Limit Fault] is disabled.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the length of time that CP2 [Comparator2 Limit Fault] is disabled.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MFDO for bit 0 of MEMOBUS register 15E0 (Hex.).
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the MFDO for bit 1 of MEMOBUS register 15E0 (Hex.).
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the MFDO for bit 2 of MEMOBUS register 15E0 (Hex.).
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the second function for terminal MA/MB-MC. Outputs the logical calculation
results of the terminals assigned to functions by H2-01 [Term MA,MB,MC Function
Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the logical operation for the functions set in H2-01 [Term MA,MB,MC Function
Selection] and H2-60 [Term MA,MB,MC Secondary Function].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum ON time that the drive uses to output the logical calculation results
from terminal MA/MB-MC.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the second function for terminal P1-C1. Outputs the logical calculation results of
the terminals assigned to functions by H2-02 [Term P1 Function Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the logical operation for the functions set in H2-02 [Term P1 Function Selection]
and H2-63 [Terminal P1 Secondary Function].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum ON time used to output the logical calculation results from terminal
P1-C1.
11.10 H: Terminal Functions
Default
Ref.
(Range)
0.0%
625
(0.0 - 300.0%)
0.0%
625
(0.0 - 300.0%)
0.0%
625
(0.0 - 10.0%)
0.0 s
625
(0.0 - 600.0 s)
0.0 s
625
(0.0 - 600.0 s)
0.0s
626
(0.0 - 10.0 s)
4
626
(0 - 4)
0.0s
626
(0.0 - 10.0 s)
4
626
(0 - 4)
0.0 s
627
(0.0 - 1000.0 s)
0.0 s
627
(0.0 - 1000.0 s)
F
627
(0 - 1FF)
F
627
(0 - 1FF)
F
627
(0 - 1FF)
F
627
(0 - FF)
0
627
(0 - 8)
0.1 s
628
(0.0 - 25.0 s)
F
628
(0 - FF)
0
628
(0 - 8)
0.1 s
628
(0.0 - 25.0 s)
11
375