7.3 List of Fault, Minor Fault, Alarm, and Error Codes
Display (Hex.)
oL4 (000E)
Overtorque Detection 2
oL5 (003D)
Mechanical Weakening Detection 1
oL5 (0044)
Mechanical Weakening Detection 1
oL7 (002B)
High Slip Braking Overload
oPE01
Drive Capacity Setting Fault
oPE02
Parameter Range Setting Error
oPE03
Multi-Function Input Setting Err
oPE05
Run Cmd/Freq Ref Source Sel Err
oPE07
Analog Input Selection Error
oPE08
Parameter Selection Error
oPE09
PID Control Selection Fault
oPE10
V/f Data Setting Error
oPE11
Carrier Frequency Setting Error
oPE13
Pulse Monitor Selection Error
oPE16
Energy Saving Constants Error
oPE33
Digital Output Selection Error
oPr (001E)
Keypad Connection Fault
oS (0010)
Overspeed
oS (0018)
Overspeed
ov (0002)
Overvoltage
ov (0008)
Overvoltage
PASS
Modbus Communication Test
PE1 (0047)
PLC Faults
PE2 (0048)
PF (0047)
Input Phase Loss
PF (001B)
Input Phase Loss
PWEr
DWEZ Password Mismatch
rdEr
Error Reading Data
rF (004E)
Braking Resistor Fault
rH (0010)
Braking Resistor Overheat
rr (000F)
Dynamic Braking Transistor Fault
rUn (001B)
Motor Switch during Run
SC (0005)
Short Circuit/IGBT Failure
SCF (040F)
Safety Circuit Fault
SE (0020)
Modbus Test Mode Error
SEr (003B)
Speed Search Retries Exceeded
SToF (003B)
Safe Torque OFF
STPo (0037)
Motor Step-Out Detected
TiM (0089)
Keypad Time Not Set
TiM (0401)
Keypad Time Not Set
TrPC (0042)
IGBT Maintenance Time (90%)
UL3 (001E)
Undertorque Detection 1
UL3 (0029)
Undertorque Detection 1
UL4 (001F)
Undertorque Detection 2
UL4 (002A)
Undertorque Detection 2
UL5 (003E)
Mechanical Weakening Detection 2
UL5 (0045)
Mechanical Weakening Detection 2
242
Name
ALM LED
Type
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
Illuminated
Fault
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Flashing
Parameter Setting Errors
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
Flashing
Not an alarm.
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
-
Backup Function Runtime Errors
-
Backup Function Runtime Errors
Illuminated
Fault
Illuminated
Fault
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
Flashing
Alarm
Flashing
Alarm
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
Flashing
Alarm
Illuminated
Fault
YASKAWA SIEPC71061753A GA500 Technical Manual
Ref.
255
266
255
255
269
269
269
270
270
271
271
272
272
272
272
272
255
266
266
266
255
267
256
267
256
277
277
257
257
257
267
257
258
267
258
267
258
268
258
268
268
258
268
259
268
259