YASKAWA CIPR-GA50C series Technical Manual page 595

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

102 : 100/10 Mbps
Note:
Set this parameter when F7-14 = 0 or 2 [Duplex Mode Selection = Half/Half or Full/Full].
F7-16: Timeout Value
No.
Name
(Hex.)
F7-16
Timeout Value
(03F4)
Note:
Set this parameter to 0.0 to disable the connection timeout function.
F7-17: EtherNet/IP Speed Scaling Factor
No.
Name
(Hex.)
F7-17
EtherNet/IP Speed Scaling
Factor
(03F5)
F7-18: EtherNet/IP Current Scale Factor
No.
Name
(Hex.)
F7-18
EtherNet/IP Current Scale
Factor
(03F6)
F7-19: EtherNet/IP Torque Scale Factor
No.
Name
(Hex.)
F7-19
EtherNet/IP Torque Scale
Factor
(03F7)
F7-20: EtherNet/IP Power Scaling Factor
No.
Name
(Hex.)
F7-20
EtherNet/IP Power Scaling
Factor
(03F8)
F7-21: EtherNet/IP Voltage Scale Factor
No.
Name
(Hex.)
F7-21
EtherNet/IP Voltage Scale
Factor
(03F9)
F7-22: EtherNet/IP Time Scaling
No.
Name
(Hex.)
F7-22
EtherNet/IP Time Scaling
(03FA)
F7-23 to F7-32: Dynamic Out Param 1 to 10 for CommCard
No.
Name
(Hex.)
F7-23 - F7-27
Dynamic Out Param 1 to 10
for CommCard
(03FB - 03FF)
F7-28- F7-32
(0370 - 0374)
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the detection time for a communications timeout.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the scaling factor for the speed monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the scaling factor for the output current monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the scaling factor for the torque monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the scaling factor for the power monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the scaling factor for the voltage monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the scaling factor for the time monitor in the EtherNet/IP Class ID 2AH Object.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets Output Assembly 116. The drive writes the values from Output Assembly 116 to the
MEMOBUS/Modbus address register that is stored for each parameter. The drive will not write
the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus address is 0.
Description
Description
Description
Description
Description
Description
Description
Description
12.7 F: Options
Default
(Range)
0.0 s
(0.0 - 30.0 s)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
12