YASKAWA CIPR-GA50C series Technical Manual page 528

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.4 C: Tuning
Do not enable this parameter in these conditions:
• Operating a motor in the middle speed range or low speed range
• Power supply voltage is a minimum of 10% more than the motor rated voltage
When you enable this parameter, if the power supply voltage is much less than the motor rated voltage, torque
control will not be accurate.
0 : Disabled
1 : Enabled
C3-16: Vout Modulation Limit Start Lvl
No.
Name
(Hex.)
C3-16
Vout Modulation Limit
Start Lvl
(0261)
Expert
C3-17: Vout Modulation Limit Max Level
No.
Name
(Hex.)
C3-17
Vout Modulation Limit Max
Level
(0262)
Expert
C3-18: Output Voltage Limit Level
No.
Name
(Hex.)
C3-18
Output Voltage Limit Level
(0263)
Expert
C3-21: Motor 2 Slip Compensation Gain
No.
Name
(Hex.)
C3-21
Motor 2 Slip Compensation
Gain
(033E)
RUN
Note:
Correctly set these parameters before changing the slip compensation gain:
• E4-01 [Motor 2 Rated Current]
• E4-02 [Motor 2 Rated Slip]
• E4-03 [Motor 2 Rated No-Load Current]
Use these settings to adjust this parameter as necessary:
• If the motor speed is slower than the frequency reference, increase C3-01 in 0.1 unit increments.
• If the motor speed is higher than the frequency reference, decrease the setting of this parameter in 0.1-unit
increments.
C3-22: Motor 2 Slip Comp Delay Time
No.
Name
(Hex.)
C3-22
Motor 2 Slip Comp Delay
Time
(0241)
RUN
Use these settings to adjust this parameter as necessary:
• When the speed is not stable, increase the setting.
• When the slip compensation response is too slow, decrease the setting.
528
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the modulation factor that starts the output voltage limit operation when C3-05 = 1 [Output
Voltage Limit Selection = Enabled].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the modulation factor used with C3-18 [Output Voltage Limit Level] for the output voltage
limit operation when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the maximum drop width of the voltage reference when C3-05 = 1 [Output Voltage Limit
Selection = Enabled].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to change this
setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the slip compensation delay time for motor 2 when speed is unstable or when the slip
compensation response is too slow. Usually it is not necessary to change this setting.
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
90.0%
(70.0 - 90.0%)
Default
(Range)
100.0%
(85.0 - 100.0%)
Default
(Range)
90.0%
(50.0 - 100.0%)
Default
(Range)
Determined by E3-01
(0.0 - 2.5)
Default
(Range)
Determined by E3-01
(0 - 10000 ms)