• The setting in H5-25 to H5-28 and the data in the specified holding registers are as follows.
– H5-25 = 0044H: U1-05 [Motor Speed] = 60.00 Hz (6000 = 1770H)
– H5-26 = 0045H: U1-06 [Output Voltage Ref] = 200.0 V (2000 = 07D0H)
– H5-27 = 0042H: U1-03 [Output Current] = 50% of drive rated current (100% = 8192, 50% = 4096 = 1000H)
– H5-28 = 0049H: U1-10 [Input Terminal Status] = 00H
When you rewrite the parameter value with the write command through the H5-11 [Comm ENTER Command
Mode] setting, you must use the Enter command to save and enable the contents of the changes. Refer to
Comm ENTER Command Mode on page 656
Table 6.6 Message Example When Reading from More than One Holding Register/Reading the Indicated Register
Command Message
Byte
0
Slave address
1
Function code
2
Upper
Starting No.
3
Lower
4
Upper
Data Quantity
5
Lower
6
Byte No.
7
Upper
First data
8
Lower
9
Upper
Next data
10
Lower
11
Upper
CRC-16
12
Lower
13
-
14
-
15
-
16
-
Note:
The number of bytes set in the command message set the data quantity × 2 during the command message.
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
YASKAWA SIEPC71061753A GA500 Technical Manual
and
Enter Command on page 217
Response Message (When Normal)
Setting Data
(Hex.)
01
Slave address
5A
Function code
00
Register status
Data in holding
01
register 1
selected with
00
H5-25
Data in holding
02
register 2
selected with
04
H5-26
Data in holding
00
register 3
selected with
01
H5-27
Data in holding
17
register 4
selected with
70
H5-28
4F
Starting No.
43
Data Quantity
CRC-16
Register status
Data in register 1 selected with H5-25
1: Successfully read the register
0: Register read error
Data in register 2 selected with H5-26
1: Successfully read the register
0: Register read error
Data in register 3 selected with H5-27
1: Successfully read the register
0: Register read error
Data in register 4 selected with H5-28
1: Successfully read the register
0: Register read error
Not used
Not used
Not used
Not used
6.3 MEMOBUS/Modbus Communications
for more information.
Response Message (When There is a Fault)
Setting Data
(Hex.)
01
5A
0F
Data in holding
Upper
17
register 1
selected with
Lower
70
H5-25
Data in holding
Upper
07
register 2
selected with
Lower
D0
H5-26
Data in holding
Upper
10
register 3
selected with
Lower
00
H5-27
Data in holding
Upper
00
register 4
selected with
Lower
00
H5-28
Upper
00
Lower
01
CRC-16
Upper
00
Lower
02
Upper
AC
Lower
D0
H5-11:
Setting Data
(Hex.)
Slave address
01
Function code
DA
Register status
0F
Upper
17
Lower
70
Upper
07
Lower
D0
Upper
10
Lower
00
Upper
00
Lower
00
Error code
02
Upper
E9
Lower
6C
-
-
-