12.11 o: Keypad-Related Settings
o5-05: Log Monitor Data 3
No.
Name
(Hex.)
o5-05
Log Monitor Data 3
(1555)
RUN
Note:
Sets the number of the U monitor you will log.
For example, to show U1-03 [Output Current], set o5-05 = 103. When it is not necessary to set data log monitors, set this parameter to
000. You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
o5-06: Log Monitor Data 4
No.
Name
(Hex.)
o5-06
Log Monitor Data 4
(1556)
RUN
Note:
Sets the number of the U monitor you will log.
For example, to show U1-07 [DC Bus Voltage], set o5-06 = 107. When it is not necessary to set data log monitors, set this parameter to
000. You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
o5-07: Log Monitor Data 5
No.
Name
(Hex.)
o5-07
Log Monitor Data 5
(1557)
RUN
Note:
Sets the number of the U monitor you will log.
For example, to show U1-08 [Output Power], set o5-07 = 108. When it is not necessary to set data log monitors, set this parameter to
000. You cannot select U2 monitor [Fault Trace] or U3 Monitor [Fault History].
o5-08: Log Monitor Data 6
No.
Name
(Hex.)
o5-08
Log Monitor Data 6
(1558)
RUN
Note:
Set the U monitor number you want to log.
For example, to display U1-01 [Frequency Reference], set o5-08 = 101. When it is not necessary to set a data log monitor, set this
parameter to 000. You cannot set U2 Monitors [Fault Trace] or U3 Monitors [Fault History].
o5-09: Log Monitor Data 7
No.
Name
(Hex.)
o5-09
Log Monitor Data 7
(1559)
RUN
Note:
Set the U monitor number you will log.
For example, to show U1-01 [Frequency Reference], set o5-09 = 101. When it is not necessary to set data log monitor, set this
parameter to 000.
748
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
103
(000, 101 - 999)
Default
(Range)
107
(000, 101 - 999)
Default
(Range)
108
(000, 101 - 999)
Default
(Setting Range)
000
(000, 101 - 999)
Default
(Range)
000
(000, 101 - 999)