12.7 F: Options
F6-68 to F6-71: Dynamic In Assembly 159 Param 1 to 4
No.
Name
(Hex.)
F6-68 to F6-71
Dynamic In Assembly 159
Param 1 to 4
(03E3, 03E4,
03C7, and 03C8)
F6-72: PowerLink Node Address
No.
Name
(Hex.)
F6-72
PowerLink Node Address
(081B)
F7-01: IP Address 1
No.
Name
(Hex.)
F7-01
IP Address 1
(03E5)
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
• Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a different IP address for each drive on the network.
• Also set parameters F7-01 to F7-12.
F7-02: IP Address 2
No.
Name
(Hex.)
F7-02
IP Address 2
(03E6)
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
• Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a different IP address for each drive on the network.
• Also set parameters F7-01 to F7-12.
F7-03: IP Address 3
No.
Name
(Hex.)
F7-03
IP Address 3
(03E7)
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
• Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a different IP address for each drive on the network.
• Also set parameters F7-01 to F7-12.
F7-04: IP Address 4
No.
Name
(Hex.)
F7-04
IP Address 4
(03E8)
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
• Use parameters F7-01 to F7-04 [IP Address 4] to set the IP Address. Be sure to set a different IP address for each drive on the network.
• Also set parameters F7-01 to F7-12.
592
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets Configurable Inputs 1 to 4 written to the MEMOBUS register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the node ID for PowerLink communication.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the first octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the second octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the third octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the fourth octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
Description
Description
Description
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
0000h
(0000h - FFFFh)
Default
(Range)
0
(0 - 255)
Default
(Range)
192
(0 - 255)
Default
(Range)
168
(0 - 255)
Default
(Range)
1
(0 - 255)
Default
(Range)
20
(0 - 255)