YASKAWA CIPR-GA50C series Technical Manual page 400

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

11.12 n: Special Adjustment
No.
Name
(Hex.)
n8-72
Speed Estimation
Method Select
(0655)
Expert
n8-74
Light Load Iq Level
(05C3)
Expert
n8-75
Medium Load Iq Level
(low)
(05C4)
Expert
n8-77
Heavy Load Iq Level
(05CE)
Expert
n8-78
Medium Load Id Current
(05F4)
RUN
Expert
n8-79
Pull-in Current @
Deceleration
(05FE)
n8-84
Polarity Detection
Current
(02D3)
Expert
n8-87
Output Voltage Limit
Method
(02BC)
n8-88
Vout Limit Switching
Level
(02BD)
n8-89
Vout Limit Switching
Hysteresis
(02BE)
n8-90
Vout Limit Switching
Speed
(02BF)
n8-91
Id Limit at Voltage
Saturation
(02F7)
400
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Selects the speed estimation method. Usually it is not necessary to change this setting.
0 : Method 1
1 : Method 2
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Set n8-48 [Pull-in/Light Load Id Current] to the percentage of load current (q-axis
current) that you will apply, where E5-03 [Motor Rated Current (FLA)] = a setting
value of 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Set n8-78 [Medium Load Id Current] to the percentage of load current (q-axis current)
that you will apply, where E5-03 [Motor Rated Current (FLA)] = a setting value of
100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Set n8-49 [Heavy Load Id Current] to the percentage of load current (q-axis current)
that you will apply, where E5-03 [Motor Rated Current (FLA)] = a setting value of
100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the level of the pull-in current as a percentage, where E5-03 [PM Motor Rated
Current (FLA)] = 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the pull-in current that can flow during deceleration as a percentage of the E5-03
[PM Motor Rated Current (FLA)].
Note:
When n8-79 = 0, the drive will use the value set in n8-51 [Pull-in Current @
Acceleration].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the current that the drive uses to estimate the initial motor magnetic pole as a
percentage where E5-03 [PM Motor Rated Current (FLA)] = 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the method of output voltage limit. If there is vibration in the constant output
range, set Feedforward Method. Usually it is not necessary to change this setting.
0 : Feedback Method
1 : Feedforward Method
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the current level at which output voltage limit sequence selection occurs as a
percentage where the motor rated current is 100%. Normally there is no need to change
this setting.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor
rated current.
• A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
• A1-02 = 8[EZOLV]: E9-06 [PM Motor Rated Current (FLA)]
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the hysteresis width of the current level at which output voltage limit sequence
selection occurs as a percentage where the motor rated current is 100%. Normally there
is no need to change this setting.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor
rated current.
• A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
• A1-02 = 8[EZOLV]: E9-06 [PM Motor Rated Current (FLA)]
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the speed level at which output voltage limit sequence selection occurs as a
percentage where the maximum output frequency is 100%. Usually it is not necessary to
change this setting.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the
maximum output frequency.
• A1-02 = 5, 6 [OLV/PM, AOLV/PM]: E1-04 [Maximum Output Frequency]
• A1-02 = 8: E9-02 [Motor Max Revolutions]
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the limit value of feedback output voltage limit Id operation. Enabled when n8-87
= 0 [Output Voltage Control Selection = Speed Feedback Form]. Usually it is not
necessary to change this setting.
Default
(Range)
1
(0, 1)
30%
(0 - 255%)
50%
(0 - 255%)
90%
(0 - 255%)
0%
(0 - 255%)
50%
(0 - 200%)
100%
(0 - 150%)
0
(0, 1)
400%
(0 - 400%)
3%
(0 - 400%)
200%
(0 - 200%)
-50%
(-200 - 0%)
YASKAWA SIEPC71061753A GA500 Technical Manual
Ref.
725
725
725
726
726
726
726
726
727
727
727
727

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents