YASKAWA CIPR-GA50C series Technical Manual page 385

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

No.
Name
(Hex.)
H7-10
Virtual Multi-Function
Output 1
(11A4)
Expert
H7-11
Virtual Output 1 Delay
Time
(11A5)
Expert
H7-12
Virtual Multi-Function
Output 2
(11A6)
Expert
H7-13
Virtual Output 2 Delay
Time
(11A7)
Expert
H7-14
Virtual Multi-Function
Output 3
(11A8)
Expert
H7-15
Virtual Output 3 Delay
Time
(11A9)
Expert
H7-16
Virtual Multi-Function
Output 4
(11AA)
Expert
H7-17
Virtual Output 4 Delay
Time
(11AB)
Expert
H7-30
Virtual Analog Input
Selection
(1177)
Expert
H7-31
Virtual Analog Input
Gain
(1178)
RUN
Expert
H7-32
Virtual Analog Input
Bias
(1179)
RUN
Expert
H7-40
Virtual Analog Out
Signal Select
(1163)
H7-41
Virtual Analog Output
Function
(1164)
H7-42
Virtual Analog Output
FilterTime
(1165)
YASKAWA SIEPC71061753A GA500 Technical Manual
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for virtual digital output 1.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum ON time for virtual digital output 1.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for virtual digital output 2.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the minimum ON time for virtual digital output 2.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for virtual digital output 3.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum ON time for virtual digital output 3.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for virtual digital output 4.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum ON time for virtual digital output 4.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the virtual analog input function.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the virtual analog input gain.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the virtual analog input bias.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the signal level of the virtual analog output.
0 : 0 to 100% (Absolute Value)
1 : -100 to 100%
2 : 0 to 100% (Lower Limit at 0)
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the monitor to be output from the virtual analog output.
Set the x-xx part of the Ux-xx [Monitor]. For example, set H7-41 = 102 to monitor U1-
02 [Output Frequency].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time constant for a primary filter of the virtual analog output.
11.10 H: Terminal Functions
Default
Ref.
(Range)
F
662
(0 - 1A7)
0.1 s
662
(0.0 - 25.0 s)
F
663
(0 - 1A7)
0.1 s
663
(0.0 - 25.0 s)
F
663
(0 - 1A7)
0.1 s
663
(0.0 - 25.0 s)
F
663
(0 - 1A7)
0.1 s
663
(0.0 - 25.0 s)
F
663
(0 - 32)
100.0%
663
(-999.9 - 999.9%)
0.0%
664
(-999.9 - 999.9%)
0
664
(0 - 2)
102
664
(0 - 999)
0.00 s
664
(0.00 - 2.00 s)
11
385

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents