YASKAWA CIPR-GA50C series Technical Manual page 701

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

L7-01: Forward Torque Limit
No.
Name
(Hex.)
L7-01
Forward Torque Limit
(04A7)
RUN
Note:
• The lower torque limit is enabled when you set the torque limit by the following method.
–Set H3-02 or H3-10 = 10, 15 [MFAI Function Select = Forward Torque Limit, General Torque Limit].
–Use a communication option to set the torque limits
• You must think about drive capacity when a large quantity of torque is necessary. If you set the value too high, the drive can detect oC
[Overcurrent].
• If you set the value too low with large loads, the motor can stall.
L7-02: Reverse Torque Limit
No.
Name
(Hex.)
L7-02
Reverse Torque Limit
(04A8)
RUN
Note:
• The lower torque limit is enabled when you set the torque limit by the following method.
–Set H3-02 or H3-10 = 10, 15 [MFAI Function Select = Forward, Reverse/Regenerative Torque Limit].
–Use a communication option to set the torque limits
• You must think about drive capacity when a large quantity of torque is necessary. If you set the value too high, the drive can detect oC
[Overcurrent].
• If you set the value too low with large loads, the motor can stall.
L7-03: Forward Regenerative Trq Limit
No.
Name
(Hex.)
L7-03
Forward Regenerative Trq
Limit
(04A9)
RUN
Note:
• The lower torque limit is enabled when you set the torque limit by the following method.
–Set H3-02 or H3-10 = 10, 15 [MFAI Function Select = Forward, Reverse/Regenerative Torque Limit].
–Use a communication option to set the torque limits
• You must think about drive capacity when a large quantity of torque is necessary. If you set the value too high, the drive can detect oC
[Overcurrent].
• If you set the value too low with large loads, the motor can stall.
L7-04: Reverse Regenerative Trq Limit
No.
Name
(Hex.)
L7-04
Reverse Regenerative Trq
Limit
(04AA)
RUN
Note:
• Use this method to set the torque limit and enable the lower torque limit:
–Set H3-02 or H3-10 = 10, 15 [MFAI Function Select = Forward, Reverse/Regenerative Torque Limit].
–Use a communication option to set the torque limits
• You must think about drive capacity when a large quantity of torque is necessary. If you set the value too high, the drive can detect oC
[Overcurrent].
• If you set the value too low with large loads, the motor can stall.
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the torque limit value for forward motoring as a percentage, where motor rated torque is the
100% value.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the torque limit value for reversed motoring as a percentage, where motor rated torque is the
100% value.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the torque limit value for forward regenerative conditions as a percentage of the motor rated
torque.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the torque limit value for reversed regenerative conditions as a percentage of the motor rated
torque.
12.9 L: Protection Functions
Description
Description
Description
Description
Default
(Range)
200%
(0 - 300%)
Default
(Range)
200%
(0 - 300%)
Default
(Range)
200%
(0 - 300%)
Default
(Range)
200%
(0 - 300%)
12
701