11.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
No.
Name
OVSuppression Accel/
L3-21
Decel P Gain
Current Suppression
L3-36
Gain@Accel
Speed Agree Detection
L4-01
Level
Speed Agree Detection
L4-02
Width
Speed Agree Detection
L4-03
Level(+/-)
Speed Agree Detection
L4-04
Width(+/-)
Carrier Freq Reduction
L8-40
Off-Delay
STPo Detection Level
L8-90
(Low Speed)
Speed Response
n5-04
Frequency
Initial Pole Detection
n8-35
Method
Pull-in Current @
n8-51
Acceleration
Frequency Display Unit
o1-03
Selection
o1-04
V/f Pattern Display Unit
*1
The setting range is 0.0 to 100.0 when A1-02 = 6 [PM Advanced Open Loop Vector].
*2
The setting range is 0.0 to 40.0 when A1-02 = 6 [PM Advanced Open Loop Vector].
*3
The default setting changes when the setting for C6-01 [Normal / Heavy Duty Selection] changes.
*4
This is the value for 200 V class drives. Double the value for 400 V class drives.
*5
The setting range is -100.0 to +100.0 when A1-02 = 6 [PM Advanced Open Loop Vector].
428
Range
Unit
0.10 - 10.00
0.01
0.0 - 100.0
0.1
*1
0.0 - 400.0
0.1
*2
0.0 - 20.0
0.1
*5
-400.0 - +400.0
0.1
*2
0.0 - 20.0
0.1
0.00 - 2.00
0.01 s
0 - 5000
1
0.00 - 500.00
0.00 Hz
0 - 2
1
0 - 200%
1
0 - 3
1
0 - 1
1
Control Method (A1-02 Setting)
OLV/PM
AOLV/PM
(5)
(6)
1.00
1.00
-
-
0.0 Hz
0.0%
2.0 Hz
4.0%
0.0 Hz
0.0%
2.0 Hz
4.0%
0.00
0.00
0
80
-
20.00
0
1
50%
0
0
1
-
1
YASKAWA SIEPC71061753A GA500 Technical Manual
EZOLV
(8)
1.00
-
0.0%
4.0%
0.0%
4.0%
0.00
-
-
-
80%
1
-