YASKAWA CIPR-GA50C series Technical Manual page 373

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

Setting Value
Function
65
KEB Ride-Thru 1
Activate (N.C.)
66
KEB Ride-Thru 1
Activate (N.O.)
67
Communications Test
Mode
68
High Slip Braking
6A
Drive Enable
75
Up 2 Command
76
Down 2 Command
77
ASR Gain (C5-03)
Select
7A
KEB Ride-Thru 2
Activate (N.C.)
7B
KEB Ride-Thru 2
Activate (N.O.)
7C
Short Circuit Braking
(N.O.)
7D
Short Circuit Braking
(N.C.)
7E
Reverse Rotation
Identifier
7F
PID Bi-Directional
Enable
90 - 96
DWEZ Digital Inputs 1
to 7
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.C.).
ON : Normal operation
OFF : Deceleration during momentary power loss
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.O.).
ON : Deceleration during momentary power loss
OFF : Normal operation
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Set the function for the drive to self-test RS-485 serial communications operation.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the command to use high-slip braking to stop the motor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to show dnE [Drive Enabled] on the keypad and ignore Run commands when the terminal is
OFF.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function to increase the frequency reference bias value to accelerate the motor when the terminal is
activated. Set this function and H1-xx = 76 [Down 2 Command] together.
Note:
When you use this function, use d4-08 and d4-09 [Up/Down 2 Bias Upper Limit/Lower Limit] to set the
optimal bias limit value.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to decrease the frequency reference bias value to decelerate the motor when the terminal is
activated. Set this function and H1-xx = 75 [Up 2 Command] at the same time.
Note:
When you use this function, use d4-08 and d4-09 [Up/Down 2 Bias Upper Limit/Lower Limit] to set the
optimal bias limit value.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to switch the ASR proportional gain set in C5-01 [ASR Proportional Gain 1] and C5-03 [ASR
Proportional Gain 2].
ON : C5-03
OFF : C5-01
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.C.).
ON : Normal operation
OFF : Deceleration during momentary power loss
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets operation of the KEB2 function through the KEB Ride-Thru 2 (N.O.).
ON : Deceleration during momentary power loss
OFF : Normal operation
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets operation of Short Circuit Braking (N.O.).
ON : Short Circuit Braking is enabled.
OFF : Normal operation
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM
motor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets operation of Short Circuit Braking (N.C.).
ON : Normal operation
OFF : Short Circuit Braking is enabled.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM
motor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Set the motor rotation direction when you use Simple Closed Loop V/f Control method.
ON : Reverse run
OFF : Forward run
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets operation of the PID Bi-Directional function.
ON : Enabled
OFF : Disabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets digital inputs used with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
11.10 H: Terminal Functions
Description
Ref.
615
616
616
616
616
616
618
618
618
618
618
619
619
619
619