YASKAWA CIPR-GA50C series Technical Manual page 625

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

H2-26: Comparator 2 Monitor Selection
No.
Name
(Hex.)
H2-26
Comparator 2 Monitor
Selection
(1546)
Note:
• The configurable monitor changes when the control method changes.
• When you use the terminal in through mode, set this parameter to 000 or 031. You can set the terminal output level from the PLC
through MEMOBUS/Modbus communications or the communication option.
• For information on the comparator function, refer to
H2-27: Comparator 2 Lower Limit
No.
Name
(Hex.)
H2-27
Comparator 2 Lower Limit
(1547)
Note:
For information on the comparator function, refer to
H2-28: Comparator 2 Upper Limit
No.
Name
(Hex.)
H2-28
Comparator 2 Upper Limit
(1548)
Note:
For information on the comparator function, refer to
H2-29: Comparator 2 Hysteresis
No.
Name
(Hex.)
H2-29
Comparator 2 Hysteresis
(1549)
Note:
For information on the comparator function, refer to
H2-30: Comparator 2 On-Delay Time
No.
Name
(Hex.)
H2-30
Comparator 2 On-Delay
Time
(154A)
Note:
For information on the comparator function, refer to
H2-31: Comparator 2 Off-Delay Time
No.
Name
(Hex.)
H2-31
Comparator 2 Off-Delay
Time
(154B)
Note:
For information on the comparator function, refer to
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the monitor number for comparator 2. Set the x-xx part of the Ux-xx [Monitor]. For example,
set H2-26 = 103 to monitor U1-03 [Output Current].
66: Comparator1 on page 640
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the lower limit detection level for comparator 2 as a percentage of the full scale analog output
for the monitor selected in H2-26 [Comparator 2 Monitor Selection].
66: Comparator1 on page 640
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the upper limit detection level for comparator 2 as a percentage of the full scale analog output
for the monitor selected in H2-26 [Comparator 2 Monitor Selection].
66: Comparator1 on page 640
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the hysteresis level for comparator 2 as a percentage of the full scale analog output for the
monitor selected in H2-26 [Comparator 2 Monitor Selection].
66: Comparator1 on page 640
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the on-delay time for comparator 2.
66: Comparator1 on page 640
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the off-delay time for comparator 2.
66: Comparator1 on page 640
12.8 H: Terminal Function Selection
Description
and
67: Comparator2 on page
Description
and
67: Comparator2 on page
Description
and
67: Comparator2 on page
Description
and
67: Comparator2 on page
Description
and
67: Comparator2 on page
Description
and
67: Comparator2 on page
Default
(Range)
103
(000 - 999)
640.
Default
(Range)
0.0%
(0.0 - 300.0%)
640.
Default
(Range)
0.0%
(0.0 - 300.0%)
640.
Default
(Range)
0.0%
(0.0 - 10.0%)
640.
Default
(Range)
0.0 s
(0.0 - 600.0 s)
640.
Default
(Range)
0.0 s
(0.0 - 600.0 s)
640.
12
625

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents