YASKAWA CIPR-GA50C series Technical Manual page 399

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

No.
Name
(Hex.)
n8-39
PM Phase Compensation
Gain
(0566)
n8-41
HFI P Gain
(0568)
Expert
n8-42
HFI I Time
(0569)
Expert
n8-45
Speed Feedback
Detection Gain
(0538)
n8-47
Pull-in Current Comp
Filter Time
(053A)
n8-48
Pull-in/Light Load Id
Current
(053B)
RUN
n8-49
Heavy Load Id Current
(053C)
RUN
Expert
n8-50
Medium Load Iq Level
(High)
(053D)
Expert
n8-51
Pull-in Current @
Acceleration
(053E)
n8-54
Voltage Error
Compensation Time
(056D)
Expert
n8-55
Motor to Load Inertia
Ratio
(056E)
n8-57
HFI Overlap Selection
(0574)
n8-62
Output Voltage Limit
Level
(057D)
Expert
n8-63
Output Voltage Limit P
Gain
(057E)
Expert
n8-65
Speed Fdbk Gain @ oV
Suppression
(065C)
Expert
n8-69
Speed Observer Control
P Gain
(065D)
Expert
YASKAWA SIEPC71061753A GA500 Technical Manual
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the low-pass filter shut-off frequency for high frequency injection.
Note:
• Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-
57 = 1 [HFI Overlap Selection = Enabled] to enable this parameter.
• The drive automatically calculates this value when High Frequency Injection
Auto-Tuning completes successfully.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the response gain for the high frequency injection speed estimation.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the integral time constant for the high frequency injection speed estimation.
Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the internal speed feedback detection reduction unit gain as a magnification value.
Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the time constant the drive uses to align the pull-in current reference value with the
actual current value. Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
On the basis that parameter E5-03 [Motor Rated Current (FLA)] is the 100% value, this
parameter sets the d-axis current that flows to the motor during run at constant speed as
a percentage.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the d-axis current to that the drive will supply to the motor to run it at a constant
speed with a heavy load. Considers E5-03 [PM Motor Rated Current (FLA)] to be
100%. Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the load current level at which heavy load control starts where E5-03 [Motor Rated
Current (FLA)] is 100%. Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the pull-in current allowed to flow during acceleration/deceleration as a percentage
of the motor rated current.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor
rated current.
• A1-02 = 5 [OLV/PM]: E5-03 [Motor Rated Current (FLA)]
• A1-02 = 8 [EZOLV]: E9-06 [Motor Rated Current (FLA)]
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time constant that the drive uses when adjusting for voltage errors.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the ratio between motor inertia and machine inertia.
0 : Below 1:10
1 : Between 1:10 and 1:30
2 : Between 1:30 and 1:50
3 : Beyond 1:50
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that detects motor speed with high frequency injection.
Note:
When you set n8-57 = 1, doHigh Frequency Injection Auto-Tuning.
0 : Disabled
1 : Enabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the output voltage limit to prevent saturation of the output voltage. Usually it is not
necessary to change this parameter.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the proportional gain for output voltage control. Usually it is not necessary to
change this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the gain of internal speed feedback detection suppression while the overvoltage
suppression function is operating as a magnification value. Usually it is not necessary to
change this parameter.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Usually it is not necessary to change this setting. Sets the Proportional gain that the
drive uses for speed estimation.
11.12 n: Special Adjustment
Default
Ref.
(Range)
250 Hz
721
(0 - 1000 Hz)
2.5
722
(-10.0 - +10.0)
0.10 s
722
(0.00 - 9.99 s)
0.80
722
(0.00 - 10.00)
5.0 s
722
(0.0 - 100.0 s)
30%
722
(0 - 200%)
Determined by E5-01
723
(-200.0 - +200.0%)
80%
723
(50 - 255)
Determined by A1-02
723
(0 - 200%)
1.00 s
723
(0.00 - 10.00 s)
0
723
(0 - 3)
0
724
(0, 1)
200 V Class: 200.0 V,
724
400 V: 400.0 V
(200 V Class: 0.0 to
230.0 V, 400 V Class:
0.0 to 460.0 V)
1.00
725
(0.00 - 100.00)
1.50
725
(0.00 - 10.00)
1.00
725
(0.00 - 20.00)
11
399