H5-17: ENTER command response @CPU BUSY
No.
Name
(Hex.)
H5-17
ENTER command response
@CPU BUSY
(11A1)
Expert
0 : Ignore Command(No ROM/RAM Write)
1 : Write to RAM Only
H5-18: Motor Speed Filter over Comms
No.
Name
(Hex.)
H5-18
Motor Speed Filter over
Comms
(11A2)
Sets the filter time constant when you monitor the output frequency or motor speed during MEMOBUS/Modbus
communications or use of the communication option.
These are the MEMOBUS registers:
• 003EH (Output Frequency)
• 003FH (Output Frequency)
• 0044H (U1-05: Motor Speed)
• 00ACH (U1-05: Motor Speed)
• 00ADH (U1-05: Motor Speed)
H5-20: Communication Parameters Reload
No.
Name
(Hex.)
H5-20
Communication Parameters
Reload
(0B57)
0 : Reload at Next Power Cycle
1 : Reload Now
Note:
• The setting value automatically returns to H5-20 = 0 after you enable MEMOBUS/Modbus communications parameter changes.
• The setting values of these parameters are enabled:
–H5-01 [Drive Node Address]
–H5-02 [Communication Speed Selection]
–H5-03 [Communication Parity Selection]
–H5-06 [Drive Transmit Wait Time]
H5-22: Speed Search from MODBUS
No.
Name
(Hex.)
H5-22
Speed Search from
MODBUS
(11CF)
0 : Disabled
1 : Enabled
If you set H5-22 = 1 and H1-xx = 62 [Speed Search from Fref] at the same time, the drive will detect oPE03
[Multi-Function Input Setting Err].
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets operation when the EEPROM write command is sent without EEPROM write available.
Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the filter time constant used when monitoring motor speed during MEMOBUS/Modbus
communications or with a communication option.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to immediately enable updated MEMOBUS/Modbus communications
parameters.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enables the MEMOBUS/Modbus communication register Speed Search function (bit0 of
15DFH).
12.8 H: Terminal Function Selection
Description
Description
Description
Description
Default
(Range)
0
(0, 1)
Default
(Range)
0 ms
(0 - 100 ms)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)