YASKAWA CIPR-GA50C series Technical Manual page 561

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD : 2001 - 2021, B001 - B018, 4001 - 4012
ND : 2001 - 2018, B001 - B012, 4001 - 4009
B : High Trq, 60 Hz, 65% Vmin Boost
Use this pattern when high torque is necessary during start up.
Select this pattern only in these conditions:
• The wiring distance between the drive and motor is 150 m (492.1 ft) minimum
• There is an AC reactor connected to the drive output.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD : 2001 - 2021, B001 - B018, 4001 - 4012
ND : 2001 - 2018, B001 - B012, 4001 - 4009
C : Const Trq, 60 Hz base, 90 Hz max
Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate
at more than 60 Hz.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD : 2001 - 2021, B001 - B018, 4001 - 4012
ND : 2001 - 2018, B001 - B012, 4001 - 4009
D : Const Trq, 60 Hz base, 120 Hz max
Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate
at more than 60 Hz.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
YASKAWA SIEPC71061753A GA500 Technical Manual
12.6 E: Motor Parameters
HD : 2030 - 2082, 4018 - 4060
ND : 2021 - 2082, 4012 - 4060
HD : 2030 - 2082, 4018 - 4060
ND : 2021 - 2082, 4012 - 4060
HD : 2030 - 2082, 4018 - 4060
ND : 2021 - 2082, 4012 - 4060
12
561

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents