O5: Log Function - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.11 o: Keypad-Related Settings
1 : Reset
Resets the values of U4-02, U4-24, and U4-25. After the reset, the drive automatically resets o4-13 to 0.
o4-22: Time Format
No.
Name
(Hex.)
o4-22
Time Format
(154F)
RUN
Sets the display of the time shown in the upper-left of the LCD keypad screen.
0 : 24 Hour Clock
1 : 12 Hour Clock
2 : 12 Hour JP Clock
o4-23: Date Format
No.
Name
(Hex.)
o4-23
Date Format
(1550)
RUN
Sets the date format that the drive uses for the fault history and other records.
0 : YYYY/MM/DD
1 : DD/MM/YYYY
2 : MM/DD/YYYY
o4-24: bAT Detection Selection
No.
Name
(Hex.)
o4-24
bAT Detection Selection
(310F)
RUN
0 : Disable
The drive will not detect bAT or TiM.
1 : Enable (Alarm Detected)
The keypad shows bAT or TiM and the drive continues operation. The output terminal set to Alarm [H2-01 to H2-
03 = 10] activates.
2 : Enable (Fault Detected)
The output turns off and the motor coasts to stop. The output terminal set for Fault [H2-01 to H2-03 = E]
activates.

o5: Log Function

The data log function saves drive status information as a CSV file in the micro SD memory card in the keypad.
Monitors Ux-xx are the source of data log information. You can record a maximum of 10 monitors.
Change the LCD keypad screen from the main menu to the Diagnostic Tools screen and select the data log
function. Set the number of the monitor to record and the sampling time, then start to record the data log.
No.
o5-03
Log Monitor Data 1
o5-04
Log Monitor Data 2
o5-05
Log Monitor Data 3
o5-06
Log Monitor Data 4
o5-07
Log Monitor Data 5
744
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the time display format. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the date display format. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the operation when the drive detects bAT [Keypad Battery Low Voltage] and TiM [Keypad
Time Not Set]. This parameter is only available when you use an LCD keypad.
Table 12.74 Setting Parameters for Data Log Items
Name
Description
Description
Description
Default
101
U1-01 [Frequency Reference]
102
U1-02 [Output Frequency]
103
U1-03 [Output Current]
107
U1-07 [DC Bus Voltage]
108
U1-08 [Output Power]
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
0
(0 - 2)
Default
(Range)
0
(0 - 2)
Default
(Range)
0
(0 - 2)