11.20 Parameters Changed by E1-03 [V/f Pattern Selection]

11.20 Parameters Changed by E1-03 [V/f Pattern Selection]

The values for parameters A1-02 [Control Method Selection] and E1-03 [V/f Pattern Selection] change the default
settings for the parameters in these tables:
Table 11.3 Parameters Changed by E1-03 (2001 to 2021, B001 to B018, and 4001 to 4012)
No.
Unit
E1-03
0
1
E1-04
Hz
50.0
60.0
60.0
E1-05
V
200.0
200.0
200.0
*3
E1-06
Hz
50.0
60.0
50.0
E1-07
Hz
2.5
3.0
3.0
E1-08
V
16.0
16.0
16.0
*3
E1-09
Hz
1.3
1.5
1.5
E1-10
V
12.0
12.0
12.0
*3
*1
These values are the default settings for E1-04 to E1-10 and E3-04 to E3-10 [V/f Pattern for Motor 2]. These settings are the same as
those for the V/f pattern when E1-03 = 0 [Const Trq, 50 Hz base, 60Hz max].
*2
The default setting varies depending on the setting of E5-01 [PM Motor Code Selection].
*3
This is the value for 200 V class drives. Double the value for 400 V class drives.
Table 11.4 Parameters Changed by E1-03 (2030 to 2082 and 4018 to 4060)
No.
Unit
E1-03
0
1
E1-04
Hz
50.0
60.0
60.0
E1-05
V
200.0
200.0
200.0
*3
E1-06
Hz
50.0
60.0
50.0
E1-07
Hz
2.5
3.0
3.0
E1-08
V
14.0
14.0
14.0
*3
E1-09
Hz
1.3
1.5
1.5
E1-10
V
7.0
7.0
7.0
*3
*1
These values are the default settings for E1-04 to E1-10 and E3-04 to E3-10 [V/f Pattern for Motor 2]. These settings are the same as
those for the V/f pattern when E1-03 = 0 [Const Trq, 50 Hz base, 60Hz max].
*2
The default setting varies depending on the setting of E5-01 [PM Motor Code Selection].
*3
This is the value for 200 V class drives. Double the value for 400 V class drives.
430
2
3
4
5
6
72.0
50.0
50.0
60.0
200.0
200.0
200.0
200.0
60.0
50.0
50.0
60.0
3.0
25.0
25.0
30.0
16.0
35.0
50.0
35.0
1.5
1.3
1.3
1.5
12.0
8.0
9.0
8.0
2
3
4
5
6
72.0
50.0
50.0
60.0
200.0
200.0
200.0
200.0
60.0
50.0
50.0
60.0
3.0
25.0
25.0
30.0
14.0
35.0
50.0
35.0
1.5
1.3
1.3
1.5
7.0
6.0
7.0
6.0
Setting Value
7
8
9
A
B
60.0
50.0
50.0
60.0
60.0
200.0
200.0
200.0
200.0
200.0
60.0
50.0
50.0
60.0
60.0
30.0
2.5
2.5
3.0
3.0
50.0
19.0
24.0
19.0
24.0
1.5
1.3
1.3
1.5
1.5
9.0
12.0
13.0
12.0
15.0
Setting Value
7
8
9
A
B
60.0
50.0
50.0
60.0
60.0
200.0
200.0
200.0
200.0
200.0
60.0
50.0
50.0
60.0
60.0
30.0
2.5
2.5
3.0
3.0
50.0
18.0
23.0
18.0
23.0
1.5
1.3
1.3
1.5
1.5
7.0
9.0
11.0
9.0
13.0
YASKAWA SIEPC71061753A GA500 Technical Manual
Control Method (A1-
F
OLV
C
D
E
*1
(2)
90.0
120.0
180.0
50.0
50.0
200.0
200.0
200.0
200.0
200.0
60.0
60.0
60.0
50.0
50.0
3.0
3.0
3.0
2.5
3.0
16.0
16.0
16.0
16.0
14.4
1.5
1.5
1.5
1.3
0.5
12.0
12.0
12.0
12.0
3.0
Control Method (A1-
F
OLV
C
D
E
*1
(2)
90.0
120.0
180.0
50.0
50.0
200.0
200.0
200.0
200.0
200.0
60.0
60.0
60.0
50.0
50.0
3.0
3.0
3.0
2.5
3.0
14.0
14.0
14.0
14.0
13.2
1.5
1.5
1.5
1.3
0.5
7.0
7.0
7.0
7.0
2.4
02 Setting)
OLV/
AOL
PM
V/PM
(5)
(6)
*2
*2
*2
*2
*2
*2
-
-
-
-
*2
*2
-
-
02 Setting)
OLV/
AOL
PM
V/PM
(5)
(6)
*2
*2
*2
*2
*2
*2
-
-
-
-
*2
*2
-
-