to switch between LOCAL and REMOTE Modes when the drive is stopped. When LOCAL
Mode is selected,
WARNING! Sudden Movement Hazard. If you change the control source when b1-07 = 1 [LOCAL/REMOTE Run Selection =
Accept Existing RUN Command], the drive can start suddenly. Before you change the control source, remove all personnel from
the area around the drive, motor, and load. Sudden starts can cause serious injury or death.
WARNING! Sudden Movement Hazard. Fully examine all mechanical and electrical connections before you change o2-01 [LO/
RE Key Function Selection] or b1-07 [LOCAL/REMOTE Run Selection]. Sudden starts can cause serious injury or death. If b1-
07 = 1 [Accept Existing RUN Command] and there is an active Run command when you switch from LOCAL to REMOTE Mode,
the drive can start suddenly.
Function Selection
o2-01 = 0 [Disabled]
o2-01 = 1 [Enabled]
o2-02: STOP Key Function Selection
No.
Name
(Hex.)
o2-02
STOP Key Function
Selection
(0506)
0 : Disabled
1 : Enabled
stays enabled when the Run command source has not been assigned to the keypad.
To start the drive again after you push
again.
o2-03: User Parameter Default Value
No.
Name
(Hex.)
o2-03
User Parameter Default
Value
(0507)
When you set o2-03 = 1 [Set defaults], the drive saves changed parameter settings as user parameter setting
values in a part of the memory that is isolated from drive parameters.
When you set A1-03 = 1110 [Initialize Parameters = User Initialization] to initialize the drive, the drive resets the
internal parameter setting values to those user parameter setting values.
0 : No change
1 : Set defaults
Saves changed parameter setting values as user default settings.
Set o2-03 = 1 then push
03 automatically resets to 0.
2 : Clear all
Deletes all of the saved user parameter setting values.
Set o2-03 = 2 then push
0. If you delete the user parameter setting values, you cannot set A1-03 = 1110 to initialize parameters.
YASKAWA SIEPC71061753A GA500 Technical Manual
on the keypad will come on.
Table 12.73 Function Settings with o2-01 and b1-07
LOCAL/REMOTE Run Selection
b1-07 = 0 [Disregard Existing RUN
Command]
b1-07 = 1 [Accept Existing RUN
Command]
b1-07 = 0 [Disregard Existing RUN
Command]
b1-07 = 1 [Accept Existing RUN
Command]
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to use
for the drive is REMOTE (external) and not assigned to the keypad.
to stop operation, turn the external Run command OFF and ON
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function to keep the settings of changed parameters as user parameter defaults to use
during initialization.
to save the user parameter setting values. After the drive saves the setting value, o2-
to clear the user parameter setting values. The drive will automatically reset o2-03 to
12.11 o: Keypad-Related Settings
Switching from LOCAL Mode to
REMOTE Mode
The drive will not switch modes.
The drive will not start operating although
the Run command is active. When you set
Run command to active again, the drive
will start to run.
When the Run command is active, the
drive will start to run immediately when
the mode switches from LOCAL to
REMOTE.
Description
on the keypad to stop the drive when the Run command source
Description
Switching from REMOTE Mode to
LOCAL Mode
The drive will not switch modes.
The drive cannot operate because the Run
command is not enabled.
The drive cannot operate because the Run
command is not enabled.
Default
(Setting Range)
1
(0, 1)
Default
(Range)
0
(0 - 2)
737