Note:
• You can show a maximum of three selected monitors on one LCD keypad screen.
–When you select only one monitor, the text size of this monitor increases. For example, when o1-25 to o1-35 = 0, the text size of the
monitor saved in o1-24 increases.
–When you select two monitors, the text size of these monitors increase.
–When you select four or more monitors, the fourth monitor and all additional monitors are shown on the next screens.
• Monitors selected with o1-24 to o1-26 can be displayed as a bar graph, analog gauge, or trend plot.
–Bar graph display: 3 monitors maximum
Select with o1-24, o1-25, and o1-26.
–Analog gauge display: 1 monitor
Select with o1-24.
–Trend plot display: 2 monitors
Select with o1-24 and o1-25.
• You can only set parameters o1-24 to o1-26 with analog output monitors.
• You can set all monitors to parameters o1-27 to o1-35.
o1-36: LCD Backlight Brightness
No.
Name
(Hex.)
o1-36
LCD Backlight Brightness
(11B9)
RUN
When you decrease the setting value, the intensity of the backlight decreases.
o1-37: LCD Backlight ON/OFF Selection
No.
Name
(Hex.)
o1-37
LCD Backlight ON/OFF
Selection
(11BA)
RUN
Note:
Use o1-36 [LCD backlight adjustment] to adjust the intensity of the LCD backlight.
0 : OFF
1 : ON
Enables the automatic shut off function. The backlight will automatically turn off after the time set in o1-38 [Time
to turn off LCD backlight] is expired.
Note:
When o1-37 = 1 and the backlight is OFF, the keys other than
When the backlight is off, push a key on the keypad to temporarily turn the backlight on. Push any key to start keypad operation, Push
to turn the backlight on, then push
o1-38: LCD Backlight Off-Delay
No.
Name
(Hex.)
o1-38
LCD Backlight Off-Delay
(11BB)
RUN
When o1-37 = 1 [LCD backlight ON/OFF Selection= ON], the backlight will automatically turn off after the time
set in o1-38 expires.
When the backlight is off, push a key on the keypad to temporarily turn the backlight on. After the backlight turns
on, it will turn off automatically after the time set in o1-38 is expired.
YASKAWA SIEPC71061753A GA500 Technical Manual
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the intensity of the LCD keypad backlight.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the automatic shut off function for the LCD backlight.
again to enter a Run command to the drive.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time until the LCD backlight automatically turns off.
12.11 o: Keypad-Related Settings
Description
Description
are disabled.
Description
Default
(Range)
3
(1 - 5)
Default
(Range)
1
(0, 1)
Default
(Range)
60 s
(10 - 300 s)