YASKAWA CIPR-GA50C series Technical Manual page 580

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.7 F: Options
Item
Applicable options
Compatible Products
Number of connected drives
Communication specifications
Commands/responses
Synchronous control
*1
Gateway Mode is not available with Yaskawa 1000-series drives or previous series drives.
Note:
• The communication speed in gateway mode is slower than the speed in fieldbus communications. Make sure that the speed is
acceptable for your system.
• Response speed with the communication option is slower than with point-to-point communications.
• Set H5-03 [Communication Parity Selection] to the same value on the master drive and slave drives.
WARNING! Injury to Personnel. Separately prepare safety protection equipment and systems, for example fast stop switches. If
the motor does not stop correctly from the disconnection of communications cable or electrical interference, it can cause serious
injury.
Configuring Gateway Mode
Table 12.50
shows sample settings to connect 4 slave drives:
F6-16
[Gateway Mode]
Drive 0
*2
1 - 4
(Master Drive)
Drive 1
0
(Slave drive)
Drive 2
0
(Slave drive)
Drive 3
0
(Slave drive)
Drive 4
0
(Slave drive)
*1
Restart the drive to apply the new settings.
*2
Specify the number of slave drives you will connect.
*3
Setting 0 will not let the drive respond to MEMOBUS/Modbus communications.
*4
Set a slave address that is different from other slave devices.
*5
Enter the same value that you use for the master drive.
*6
To correctly detect the response timeout, do not change the value of H5-06 from the default value.
580
Figure 12.63 Connection Examples in Gateway Mode
Table 12.49 Specification
All options that support the MEMOBUS access function (for example, PROFIBUS-DP, PROFINET, EtherNet/IP, EtherCAT)
Drives that can set F6-16 [Gateway Mode]
Maximum: 5 units
MEMOBUS/Modbus (RTUmode) communications
The controller can send this data to each drive (Drive 0 to Drive 4):
• Control commands: Run commands and frequency references
• Control responses: Output frequency and drive status (during run, faults)
• Read and write parameters
• Read monitors
Not supported
Table 12.50 Sample Settings for Using Gateway Mode
H5-02
[Communication
H5-01
Speed Selection]
[Drive Node
H5-03
*1
Address]
[Communication
Parity Selection]
*5
1F (Default)
*3 *4
*5
01
*3 *4
*5
02
*3 *4
*5
03
*3 *4
*5
04
Specification
*1
H5-06
H5-09
[Drive Transmit
[CE Detection
Wait Time]
Time]
5 ms (factory
*7
≥ 2.0 s
*6
default)
5 ms (factory
*7
≥ 0.9 s
*6
default)
5 ms (factory
*7
≥ 0.9 s
*6
default)
5 ms (factory
*7
≥ 0.9 s
*6
default)
5 ms (factory
*7
≥ 0.9 s
*6
default)
YASKAWA SIEPC71061753A GA500 Technical Manual
b1-01
b1-02
[Frequency
[Run Command
Reference
Selection 1]
Selection 1]
3 [Option PCB]
3 [Option PCB]
2 [Memobus/
2 [Memobus/
Modbus
Modbus
Communications]
Communications]
*8
*8
2 [Memobus/
2 [Memobus/
Modbus
Modbus
Communications]
Communications]
*8
*8
2 [Memobus/
2 [Memobus/
Modbus
Modbus
Communications]
Communications]
*8
*8
2 [Memobus/
2 [Memobus/
Modbus
Modbus
Communications]
Communications]
*8
*8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents