12.12 T: Auto-Tuning; T0: Tuning Mode Selection; T1: Induction Motor Auto-Tuning - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

12.12 T: Auto-Tuning

12.12 T: Auto-Tuning

Numbers identifying the T parameters are displayed when an LED keypad is used. The names of the parameters
are displayed on the LCD screen of the LCD keypad. Set the following.
• Induction Motor Auto-Tuning
• PM Motor Auto-Tuning
• ASR and Inertia Tuning

T0: Tuning Mode Selection

T0-00: Tuning Mode Selection
When your control method supports Control Tuning, set T0-00 first. Then, set T1-00 [Motor 1/Motor 2 Selection]
to select the motor you will tune. Then, set the tuning mode in T2-01 [PM Auto-Tuning Selection] or T3-00
[Control Loop Tuning Selection].
No.
Name
(Hex.)
T0-00
Tuning Mode Selection
(1197)
0 : Motor Parameter Tuning
1 : Control Tuning
Note:
The available tuning modes are different for different control methods.

T1: Induction Motor Auto-Tuning

T1 parameters set the Auto-Tuning input data for induction motor tuning.
Note:
• The base frequency of drive dedicated motors and special motors for use with vector control may be lower than the base frequency of
general-purpose motors, which is 50 Hz or 60 Hz. In such cases, this lower frequency is used as the value for E1-06 [Base Frequency]
and E1-04 [Maximum Output Frequency] after Auto-Tuning completes. If the maximum output frequency is too low and causes
problems, change the setting of E1-04 after Auto-Tuning completes.
• The following induction motor parameters are set automatically.
–E1-xx [V/f Pattern for Motor 1]
–E2-xx [Motor Parameters]
–E3-xx [V/f Pattern for Motor 2]
–E4-xx [Motor 2 Parameters]
T1-00: Motor 1/Motor 2 Selection
No.
Name
(Hex.)
T1-00
Motor 1/Motor 2 Selection
(0700)
Note:
SetH1-xx = 16 [Motor 2 Selection] to enable this parameter. When H1-xx ≠ 16 the keypad will not show this parameter.
1 : Motor 1
Auto-Tuning automatically sets parameters E1-xx and E2-xx for motor 1.
2 : Motor 2
Auto-Tuning automatically sets parameters E3-xx and E4-xx for motor 2. Make sure that you connect motor 2 to
the drive for Auto-Tuning.
T1-01: Auto-Tuning Mode Selection
No.
Name
(Hex.)
T1-01
Tuning Mode Selection
(0701)
750
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the type of Auto-Tuning.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets which motor to tune when motor 1/2 switching is enabled.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the type of Auto-Tuning.
Description
Description
Description
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
(Range)
0
(0, 1)
Default
(Range)
1
(1, 2)
Default
(Range)
Determined by A1-02
(Determined by A1-02)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series