H4: Analog Outputs - YASKAWA AC Drive-A1000 Technical Manual

High performance vector control drive
Table of Contents

Advertisement

B.9 H Parameters: Multi-Function Terminals
H3-oo
Function
Setting
10
Forward torque limit
11
Reverse torque limit
12
Regenerative torque limit
13
Torque reference/Torque limit
14
Torque compensation
15
General torque limit
16
Differential PID feedback
1F
Through mode
DriveWorksEZ
30 to 32
analog input 1 to 3
u

H4: Analog Outputs

No.
(Addr.
Name
Hex)
Multi-Function Analog
H4-01
Output Terminal FM
(41D)
Monitor Selection
H4-02
Multi-Function Analog
(41E)
Output Terminal FM Gain
H4-03
Multi-Function Analog
(41F)
Output Terminal FM Bias
Multi-Function Analog
H4-04
Output Terminal AM
(420)
Monitor Selection
H4-05
Multi-Function Analog
(421)
Output Terminal AM Gain
H4-06
Multi-Function Analog
(422)
Output Terminal AM Bias
424
H3 Multi-Function Analog Input Settings
V/f
V/f
V/f w PG
V/f w PG
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
10 V = Motor rated torque
V/f
V/f
V/f w PG
V/f w PG
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
10 V = Motor rated torque
V/f
V/f
V/f w PG
V/f w PG
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
10 V = Motor rated torque
V/f
V/f
V/f w PG
V/f w PG
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
10 V = Motor rated torque
V/f
V/f
V/f w PG
V/f w PG
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
10 V = Motor rated torque
V/f
V/f
V/f w PG
V/f w PG
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
10 V = Motor rated torque
All Modes
10 V = 100%
All Modes
Set this value when using the terminal in the pass-through mode.
All Modes
Output is determined by the function selected using DWEZ.
All Modes
Selects the data to be output through multi-function analog output terminal
FM.
Set the desired monitor parameter to the digits available in Uo-oo.
For example, enter "103" for U1-03.
All Modes
Sets the signal level at terminal FM that is equal to 100% of the selected
monitor value.
All Modes
Sets the signal level at terminal FM that is equal to 0% of the selected monitor
value.
All Modes
Selects the data to be output through multi-function analog output terminal
AM.
Set the desired monitor parameter to the digits available in Uo-oo.
For example, enter "103" for U1-03.
All Modes
Sets the signal level at terminal AM that is equal to 100% of the selected
monitor value.
All Modes
Sets the signal level at terminal AM that is equal to 0% of the selected monitor
value.
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual
Description
OLV
OLV
OLV
OLV
CLV
CLV
CLV
CLV
CLV/PM
CLV/PM
CLV/PM
CLV/PM
OLV
OLV
OLV
OLV
CLV
CLV
CLV
CLV
CLV/PM
CLV/PM
CLV/PM
CLV/PM
OLV
OLV
OLV
OLV
CLV
CLV
CLV
CLV
CLV/PM
CLV/PM
CLV/PM
CLV/PM
OLV
OLV
OLV
OLV
CLV
CLV
CLV
CLV
CLV/PM
CLV/PM
CLV/PM
CLV/PM
OLV
OLV
OLV
OLV
CLV
CLV
CLV
CLV
CLV/PM
CLV/PM
CLV/PM
CLV/PM
OLV
OLV
OLV
OLV
CLV
CLV
CLV
CLV
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Description
Page
233
233
233
233
233
233
233
233
233
Values
Page
Default: 102
234
Range: 000 to 999
Default: 100.0%
Min.: -999.9
234
Max.: 999.9
Default: 0.0%
Min.: -999.9
234
Max.: 999.9
Default: 103
234
Range: 000 to 999
Default: 50.0%
Min.: -999.9
234
Max.: 999.9
Default: 0.0%
Min.: -999.9
234
Max.: 999.9

Hide quick links: