Sight Glass
Item
Symptom
1
Bubbles present in sight glass
2
No bubbles present in sight glass
No temperature difference between com-
3
pressor inlet and outlet
Temperature between compressor inlet and
4
outlet is noticeably different
Immediately after air conditioning is turned
5
off, refrigerant in sight glass stays clear
When air conditioning is turned off, refriger-
6
ant foams and then stays clear
*: Bubbles in the sight glass with ambient temperatures higher than usual can be considered normal if cooling
is sufficient.
2005 CELICA (RM1131U)
AIR CONDITIONING
AIR CONDITIONING SYSTEM
ON−VEHICLE INSPECTION
1.
INSPECT REFRIGERANT VOLUME
Observe the sight glass on the liquid tube.
Test conditions:
I12988
Amount of refrigerant
Insufficient*
None, sufficient or too much
Empty or nearly empty
Correct or too much
Too much
Correct
2426
Running engine at 1,500 rpm
S
Blower speed control switch at "HI" position
S
A/C switch ON
S
Temperature control dial at "COOL" position
S
Fully open the doors
S
(1) Check for gas leakage with gas leak de-
tector and repair if necessary
(2) Add refrigerant until bubbles disappear
Refer item 3 and 4
(1) Check for gas leakage with gas leak de-
tector and repair if necessary
(2) Add refrigerant until bubbles disappear
Refer to items 5 and 6
(1) Discharge refrigerant
(2) Evacuate air and charge proper amount
or purified refrigerant
AC−3
AC2GT−05
Remedy