Siemens G130 List Manual page 1554

Hide thumbs Also See for G130:
Table of Contents

Advertisement

4 Faults and alarms
4.2 List of faults and alarms
F07446 (A)
Load gear: Position tracking cannot be reset
Message value:
%1
Message class:
Application/technological function faulted (17)
Drive object:
VECTOR_G
Component:
None
Reaction:
OFF1 (OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The position tracking cannot be reset.
Remedy:
Reset the position tracking as follows:
- select encoder commissioning (p0010 = 4).
- reset position tracking, position (p2720.2 = 1).
- deselect encoder commissioning (p0010 = 0).
Then acknowledge the fault and, if necessary, re-adjust the absolute encoder (p2507).
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F07447
Load gear: Position tracking, maximum actual value exceeded
Message value:
Component number: %1, encoder data set: %2, drive data set: %3
Message class:
Application/technological function faulted (17)
Drive object:
VECTOR_G
Component:
None
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
When the position tracking of the load gear is configured, the drive/encoder (motor encoder) identifies a maximum
possible absolute position actual value (r2723) that can no longer be represented within 32 bits.
Maximum value: p0408 * p2721 * 2^p0419
Fault value (r0949, interpret hexadecimal):
ccbbaa hex
aa = encoder data set
bb = component number
cc = drive data set
See also: p0408 (Rotary encoder pulse number), p0419 (Fine resolution absolute value Gx_XIST2 (in bits)), p2721
(Load gear rotary absolute encoder revolutions virtual)
Remedy:
- reduce the fine resolution (p0419).
- reduce the multiturn resolution (p2721).
See also: p0419 (Fine resolution absolute value Gx_XIST2 (in bits)), p2721 (Load gear rotary absolute encoder
revolutions virtual)
F07448 (A)
Load gear: Position tracking, linear axis has exceeded the maximum range
Message value:
-
Message class:
Application/technological function faulted (17)
Drive object:
B_INF, ENC, VECTOR_G
Component:
None
Reaction:
Vector: OFF1 (NONE, OFF2, OFF3)
Infeed: NONE
Acknowledge:
IMMEDIATELY
Cause:
For a configured linear axis/no modulo axis, the currently effective motor encoder (encoder 1) has exceeded the
maximum possible traversing range.
For the configured linear axis, the maximum traversing range is defined to be 64x (+/- 32x) of p0421. It should be
read in p2721 and interpreted as the number of load revolutions.
Note:
Only the motor encoder in the currently effective drive data set is monitored here. The actual effective drive data set
is displayed in x = r0051 and the corresponding motor encoder is specified in in p0187[x].
1554
Propagation:
GLOBAL
Propagation:
GLOBAL
Propagation:
GLOBAL
List Manual (LH2), 07/2016, A5E03263479A
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150