31
Bits
[31:24]
[23:0]
31
ARM DDI 0337G
Unrestricted Access
Reset state
Unpredictable
Figure 8-4 shows the bit assignments of the SysTick Reload Value Register.
24
23
Reserved
Table 8-5 describes the bit assignments of the SysTick Reload Value Register.
Field
Function
-
Reserved
RELOAD
Value to load into the SysTick Current Value Register when the counter reaches 0.
SysTick Current Value Register
Use the SysTick Current Value Register to find the current value in the register.
The register address, access type, and Reset state are:
Address
0xE000E018
Access
Read/write clear
Reset state
Unpredictable
Figure 8-5 shows the bit assignments of the SysTick Current Value Register.
24
23
Reserved
Copyright © 2005-2008 ARM Limited. All rights reserved.
Figure 8-4 SysTick Reload Value Register bit assignments
Table 8-5 SysTick Reload Value Register bit assignments
Figure 8-5 SysTick Current Value Register bit assignments
Non-Confidential
Nested Vectored Interrupt Controller
RELOAD
CURRENT
0
0
8-11