1.5
Precautions When Setting the Parameters
Observe the following precautions when setting the MP3200.
Precautions When Setting the Circuit Numbers
When assigning circuit numbers to the Motion Control and Communications Function Modules, the num-
bers must be within the following ranges.
Function Modules in
CPU Unit
Optional Modules
Precautions When Setting Module Configuration Definitions
Observe the following precautions when writing module configuration definitions.
• Write the module configuration definitions only when the high-speed scan has sufficient unused pro-
cessing time.
Otherwise, processing may exceed the time limit of the high-speed scan.
• Before writing module configuration definitions, make sure the machine is not in operation.
• Before you use the Machine Controller, save any written data to flash memory and turn the power sup-
ply to the Racks OFF and ON again.
Unit
Motion Control
SVC32, SVR32
Function Module
Communications
218IFD
Function Module
SVA-01 (SVA), SVB-01 (SVB01),
Motion Modules
SVC-01 (SVC), MPU-01 (MPUIF),
PO-01 (PO)
217IF-01 (217IF)
218IF-01 (218IF), 218IF-02 (218IFB),
260IF-01 (260IF (DeviceNet)),
261IF-01 (261IFS (Profibus)),
262IF-01 (FL-net),
Communications
263IF-01 (EtherNet/IP),
Modules
264IF-01 (EtherCAT-S),
265IF-01 (Componet),
266IF-01, 266IF-02,
215AIF-01 (MPLINK),
215AIF-01 (CP-215)
1.5 Precautions When Setting the Parameters
Precautions When Setting the Circuit Numbers
Abbreviations of Built-in Modules
Circuit
numbers
1 to 16
1 to 8
1 to 16
1 to 16
1 to 8
1
1-15