149235-1CD

AxP005: STROKE CHANGE ANSWER TIME LIMIT

When using the X2 gear mechanical stopper gun and switching gun stroke, this parameter sets the time
from the stroke-switching-sequence start until the pressure instruction end.
Setting range: 0.0 to 9.9 sec.
The initial setting is "0," with which the switching signal is output for the "stopper-type stroke switching
time" set in the file, and then the gun pressure instruction is turned OFF.
AxP006: PARITY SPECIFICATION FOR WELDING CONDITIONS
When adding the parity signal to the welding condition signal with the Power Source connected to each
welding gun, this parameter specifies odd or even parity.
Bit specification for 4 Power Sources. (0 : odd number, 1 : even number) The initial setting is "0."
0 0 0 0 0 0 0 0
| | | |
4 3 2 1
Power Source number
AxP007: ANTICIPATE TIME
When executing the GUNCL or SPOT instruction with NWAIT specified in the previous move instruction
but the time is not specified by ATT in the GUNCL or SPOT instruction, this parameter specifies the
anticipate condition (time). The initial setting is "0," with which the each instruction is executed as soon
as the taught position of the previous move instruction is reached, as normal operation.
AxP015: WELDING ERROR RESET OUTPUT TIME
This parameter sets the output time of the welding error reset signal to the Power Source when the
alarm reset signal is input.
If the setting is "0," the welding error reset signal is not output to the Power Source even if the alarm
reset signal is input.
AxP016, AxP017: ELECTRODE WEAR AMOUNT ALARM VALUE
These parameters set the electrode wear amount alarm values (AxP016: movable side, AxP017: fixed
side) at the wear detection.
8.10.4
General-purpose Application
AxP009: WORK CONTINUE PROHIBIT
This parameter specifies whether to output TOOLON instruction or not at restarting when the work is
stopped for some reasons during the output of TOOLON instruction.