Dlp- D219 Provision A Low-Order Tunnel Route - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

DLP- D219 Provision a Low-Order Tunnel Route

Step 2
Return to your originating procedure (NTP).
DLP-D219 Provision a Low-Order Tunnel Route
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In the Circuit Creation wizard in the Route Review and Edit area, click the source node icon if it is not
Step 1
already selected. Arrows indicate the available spans for routing the tunnel from the source node.
Click the arrow of the span that you want the low-order tunnel to travel. The arrow turns white. In the
Step 2
Selected Span area, the From and To fields show the slot and port that will carry the tunnel. The source
VC4 appears.
Step 3
If you want to change the source VC4, change it in the Source VC4 field; otherwise, continue with
Step
Step 4
Click Add Span. The span is added to the Included Spans list and the span arrow turns blue.
Step 5
Repeat Steps
intermediary nodes.
Return to your originating procedure (NTP).
Step 6
DLP-D220 Provision E-Series Ethernet Ports
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security
In node view, double-click the Ethernet card that you want to provision.
Step 1
Click the Provisioning > Port tabs.
Step 2
Cisco ONS 15454 SDH Procedure Guide, R7.0
19-18
Switch on PDI-P—For high-order circuits, check this box if you want traffic to switch when an
high-order payload defect indicator (PDI) is received. Unavailable for low-order circuits.
This task provisions the route for a manually routed low-order tunnel.
None
DLP-D60 Log into CTC, page 17-49
You must have the Route Review and Edit page of the Circuit Creation
wizard open.
As needed
Onsite or remote
Provisioning or higher
4.
3
and
4
until the tunnel is provisioned from the source to the destination node through all
This task enables Ethernet ports for the E-Series cards.
None
DLP-D60 Log into CTC, page 17-49
As needed
Onsite or remote
Provisioning or higher
Chapter 19
DLPs D200 to D299
78-17194-01