Dlp- D95 Provision A Low-Order Vc12 Circuit Source And Destination - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 17
DLPs D1 to D99
DLP-D95 Provision a Low-Order VC12 Circuit Source and Destination
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
After you have selected the circuit properties in the Circuit Source dialog box according to the specific
Note
circuit creation procedure, you are ready to provision the circuit source.
From the Node drop-down list, choose the node where the source will originate.
Step 1
From the Slot drop-down list, choose the slot containing the E1-N-14 card or E1-42 card where the
Step 2
circuit will originate
optical transport.
Figure 17-17
Choose the port from the Port drop-down list.
Step 3
(E1-42 card only) From the TUG3 drop-down list, choose the source TUG3.
Step 4
78-17194-01
This task provisions an electrical or optical circuit source and destination
for a low-order VC12 circuit.
None
DLP-D60 Log into CTC, page 17-49
One of the following procedures:
NTP-D81 Create an Automatically Routed Low-Order VC12 Circuit,
page 6-19
NTP-D82 Create a Manually Routed Low-Order VC12 Circuit, page
6-24
NTP-D83 Create a Unidirectional Low-Order VC12 Circuit with
Multiple Drops, page 6-27
You must have the Source page of the Circuit Creation wizard open.
As needed
Onsite or remote
Provisioning or higher
(Figure
17-17). You can also choose an STM-N card to map the VC12 to a VC4 for
Defining the Circuit Source on an E1-N-14 Card

DLP- D95 Provision a Low-Order VC12 Circuit Source and Destination

Cisco ONS 15454 SDH Procedure Guide, R7.0
17-93

Advertisement

Table of Contents
loading

Table of Contents